( ): Manual start
4.
Disconnect the charge coil coupler.
5.
Connect the digital circuit tester to the
charge coil coupler (charge coil side).
6.
Measure the charge coil resistance.
Replace the stator assembly if out of
specification.
Test harness
1
: 90890-06871
ELEC
8-9
61U5H11
Electrical system
6S380145
Charge coil resistance
(reference data):
Brown (Br)
1
– Red (R)
3
428–642
Ω
at 20°C (68°F)
Blue (L)
2
– Black/red (B/R)
4
48–72
Ω
at 20°C (68°F)
Charge coil output peak voltage:
(low-speed)
Red (R) – Brown (Br)
r/min
Unloaded
Loaded
Cranking
1,500
3,500
DC V
130
140
160
160
(100)
(80)
Charge coil output peak voltage:
(high-speed)
Black/red (B/R) – Blue (L)
r/min
Unloaded
Loaded
Cranking
1,500
3,500
DC V
45
45
160
160
(30)
(30)
Thermoswitch continuity
temperature:
Pink (P) – Black (B)
e
: 84.0–90.0 °C (183–194°F)
f
: 60.0–74.0 °C (140–165°F)
S6P28750
Checking the thermoswitch
1.
Place the thermoswitches in a container
of water and slowly heat the water.
2.
Check the switches for continuity at the
specified temperatures. Replace the ther-
moswitches if out of specification.
a
Temperature
b
Time
c
No continuity
d
Continuity
Starting system
Checking the fuse (WH, E, ET)
1.
Check the fuse (20A) for continuity.
Replace the fuse if there is no continuity.
61U5H11_08 05.10.7 3:02 PM Page 10
Summary of Contents for 115B
Page 1: ...115B SERVICE MANUAL 61U 28197 5H 11 140B E115A E115A 115B 140B ...
Page 4: ......
Page 79: ...61U5H11 4 18 9 8 7 6 5 4 3 2 1 MEMO ...
Page 136: ...POWR 5 55 61U5H11 Power unit MEMO ...
Page 159: ...61U5H11 6 22 9 8 7 6 5 4 3 2 1 Shimming Shimming 6G46090E T3 M3 M4 M1 M2 T1 T2 F R P ...
Page 255: ......