Symptom

Suggested Action

Lock does not respond – door is 

open and accessible.

• 

Press each keypad button to see if they respond when pressed.

• 

Check batteries are installed and oriented correctly (polarity) in the battery case.

• 

Check batteries are in good condition; replace batteries* if discharged.

• 

Check to see if cable is properly connected and not pinched.

Lock does not respond – door is 

locked and inaccessible. 

• 

Lock may be in Privacy mode (set from inside room). Mechanical key will grant access.

• 

Batteries may be completely discharged.

• 

Use mechanical key to gain entry and replace batteries*.

Unit chimes to indicate code accep-

tance, but the door will not open.

• 

Check to see if there is another locking device on the door.

• 

Check the door gaps for any foreign objects between door and frame.

• 

Check that the cable is firmly connected to the PC board.

Unit operates to allow access, but will 

not automatically re-lock. 

• 

Check to see if Auto Re-lock Mode is enabled. 

• 

Disable Auto Re-lock Mode to lock the door (automatically).

• 

If low battery indicator is lit (see below), change batteries*.

PIN codes will not register.

• 

PIN codes must consist of 4 to 8 digits to register.

• 

The same PIN code cannot be used for multiple users. 

• 

Registration/management of PIN codes is set at the authority of Master.

• 

Contact the Master user

• 

User codes must be entered within 20 seconds or the process will have to be restarted.

• 

The star 

(*) or pound 

 (#) cannot be used as part of the PIN code.

Upon entering a PIN code and press-

ing the star (*) key, the lock gives 

a series of beeps, flashes red and 

blue LEDs seven times, and does not 

unlock.  

• 

All Code Lockout Mode is enabled.

• 

Only the Master can enable/disable All Code Lockout Mode.

• 

Contact the Master user.

Upon entering a PIN code and press-

ing the (*) key, there are different 

tones.

• 

Check to see if either you or your group** is set at Lockout Mode.

• 

Setting/managing Lockout Mode is done through Master only. Contact the Master user.

The unit operates, but it makes  

no sound.

• 

Enable Audio Mode.

The unit displays intermittent RED 

flashes.

• 

This is the Low Battery indicator alerting that it is time to replace the batteries. Replace 

all four (4) batteries* with new AA Alkaline batteries.

Upon entering a PIN code and press-

ing the star (*) key, the unit responds  

with a series of beeps and the keypad 

flashes three times.

• 

The digits entered were incorrect or incomplete. Re-enter the correct code followed by 

the star 

 key.

** Network Module locks only

Summary of Contents for YRD210

Page 1: ...able on our website in printed Spanish and French Go to www yalerealliving com Click Product Information Documentation and then Installation Instructions Este documento está disponible en español en nuestra página de internet Vaya a www yalerealliving com Presione Información del Producto y Documentación y luego Instrucciones de Instalación Ce document est disponible sur notre site Web dans le fra...

Page 2: ... or modifications to this unit will void the the warranty FCC FCC ID U4A YRHCPZW0 Z Wave U4A YRHCPZB0 Zigbee Model s YRD210 YRD220 YRT210 or YRT220 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation T...

Page 3: ...oved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication Section 7 1 3 of RSS GEN This Device complies with Industry Canada License exempt RSS standard s Operation is subject to the following...

Page 4: ...eded Quick Start Guide Installation Instructions Door Marker Outside Escutcheon Bolt Strike Plate Screw Pack Keys Included in the box COMPONENTS AND TOOLS Inside Escutcheon Inside Mounting Plate Battery Cover 4 AA Alkaline Batteries INSTALLATION Outside Escutcheon Inside Escutcheon 4 AA Alkaline Batteries 2 Through bolts 4 screws Keys Battery Cover Bolt Strike Plate Inside Mounting Plate 3 Mountin...

Page 5: ...ove the inside mounting plate with gasket from the back door side of the inside escutcheon Battery Cover Inside Escutcheon C The outside escutcheon with gasket remains assembled B Bolt Note Bolt ships with backset in 2 3 4 posi tion If required press small black button on underside of bolt and push to shorten to 2 3 8 backset position Inside Escutcheon Mounting Plate with gasket Outside Escutcheon...

Page 6: ... cable through 2 1 8 diameter hole Figure 3A NOTE Cable goes under bolt and through Ensure that the tailpiece is oriented correctly see arrows Fig 3B INSTALL LOCK Figure 4B Figure 4A Figure 3B Figure 3A Tongue 4 Holding the outside escutcheon flush to the door position the inside mounting plate by first routing the cable and connector through the mounting plate s 1 2 hole Fig 4A and then inserting...

Page 7: ... is not smooth review the previous steps to ensure proper installation 9 Insert four 4 AA alkaline batteries Lock responds with a series of beeps red blue flash and a quick flash of all keypad LEDs Note Refer to programming instructions prior to completion of step 10 10 Install battery cover and tighten Phillips head screw 6 Attach cable assembly to the inside escutcheon PC board by lining up notc...

Page 8: ...vacy Mode Button Menu and Icons Used in This Guide Cylinder Click the indicated number Enter Master PIN code 4 8 digits in length Factory default 12345678 Press the Star key on the keypad to Enter or Accept entry Enter User PIN Can be 4 8 digits in length Press the Pound key on the keypad to enter Menu mode User Number 1 25 RF Controlled 1 250 M U Low Battery Warning 1 Lock out Mode 2 Return to pr...

Page 9: ...lt is retracted electronically activating the keypad will extend the bolt during Auto Re Lock duration or when Auto Re Lock is disabled Shutdown Time The unit will shutdown for a default of sixty 60 seconds and not allow operation after the wrong code entry limit has been met When the unit is in Shutdown the Status Indicator flashes RED and BLUE the keypad flashes as well Audio Mode Choosing Disab...

Page 10: ...egistered 1 25 followed by the key 4 Enter a 4 8 digit PIN code for the User number followed by the key Set Up User Codes Note When registering User codes the code must be entered with in 20 seconds If time expires no codes are registered and the process must be re started PIN code structure Maximum number of user codes is 250 with Network Module without Network Module maximum is 25 user codes Loc...

Page 11: ...terface PC or hand held device to en sure communication between the lock and the controller unit Master PIN Setting M M User PIN Deletion Audio Mode All Code Lock out HCP Module Setting Enable Enable Register Disable Delete Disable User Number UN 1 25 without network module 1 250 with network module 1 2 User PIN Registration Complete U Complete Auto Re lock 7 Enable Disable This function appears o...

Page 12: ...the reset button and wait while the lock tests bolt operation For security purposes it is highly recommended that the default Master Pin Code be changed before any other programming Reset Button Symptom Suggested Action Door is binding a Check that door and frame are properly aligned and door is free swinging b Check hinges They should not be loose or have excessive wear on knuckles Bolt will not ...

Page 13: ... Disable Auto Re lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN codes will not register PIN codes must consist of 4 to 8 digits to register The same PIN code cannot be used for multiple users Registration management of PIN codes is set at the authority of Master Contact the Master user User codes must be entered within 20 seconds or the proc...

Page 14: ... from cylinder Note position of ring flange in relation to cylinder How to Replace or Install Cylinder 2 5 8 66 5 For 6 pin cylinders 1 3 8 thick doors 2 7 8 73 For 6 pin cylinders 1 3 4 thick doors ONLY 1 3 16 30 For 6 pin cylinders 1 3 8 thick doors 1 7 16 36 5 For 6 pin cylinders 1 3 4 thick doors ONLY CAUTION The cylinders furnished for use in 1 3 8 doors have a tailpiece that is 1 4 shorter t...

Page 15: ...o Network Module Up to 25 Users Location Door Number User User Name User PIN Code User Type User Name User PIN Code Master User 13 User 1 User 14 User 2 User 15 User 3 User 16 User 4 User 17 User 5 User 18 User 6 User 19 User 7 User 20 User 8 User 21 User 9 User 22 User 10 User 23 User 11 User 24 User 12 User 25 ...

Page 16: ...er ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User _...

Page 17: ...ale Security Inc an ASSA ABLOY Group company Yale is a registered trademark of Yale Security Inc an ASSA ABLOY Group company All rights reserved Yale Real Living is a trademark of Yale Security Inc an ASSA ABLOY Group company Copyright 2011 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without express written permission of Yale Security Inc an A...

Reviews: