11
An ASSA ABLOY Group brand
P/N AYRD210-INST-FUL Rev B
Feature Programming Through Menu Mode Using Master Code
1. Enter the 4-8 digit Master PIN code followed by the key.
2. Enter digit corresponding to the function to be performed followed by the key.
Note: If the lock is connected to a network controller, it is recommended that it is
programmed through the centralized user interface (PC or hand-held device) to en-
sure communication between the lock and the controller unit.
Master PIN Setting
M
M
User PIN Deletion
Audio Mode
All Code Lock-out
*HCP Module Setting
Enable
Enable
Register
Disable
Delete
Disable
User Number (UN)
1~25: without network module
1~250: with network module
1
2
User PIN Registration
Complete
U
Complete
Auto Re-lock
7
Enable
Disable
*This function appears
only with network module
installed
1
Enter PIN code.
2
Complete the code entry
by pressing the key.
Unlock.
3
Open Door with PIN Code
For quiet areas, select Disable (3)
in Audio Mode.