background image

Optional

214

Plate

Parts

Right Hand Shown

2

1

80-9350-2502-010 (05-12)

 

50 Series

Non Hold Open Door Closers — 

Parallel Arm

3

4

Holes for 214

Plate only

Door

Opening

To 100°

101° to 130°

131° to 180°

*

A

9-1/4
(235)

7-3/4
(197)

5-3/4
(146)

B

7-5/8
(194)

6-1/8
(156)

4-1/8
(105)

C

8-5/8
(219)

7-1/8
(181)

5-1/8
(130)

2-3/4

(70)

3/8

(10)

1/2

(13)

7/16

(11)

2

(50)

A

1-1/2

(38)

7

(178) 4

(102)

2-1/8

(54)

3-1/4

(83)

1/2

(13)

3/4

(19)

9-1/16

(230)

C

L

C

B

Top of
Door

Door/Wall/Hardware/Jamb

*

   conditions permitting

Inches

(mm)

5

— 3 —

S

L

Place Arm on
Spindle

Rot

at

e

 

Remove Arm
from Spindle

Close Valves

L

S

Latch

Sweep

Optional

Co

ver

See Step 6 on Page 4

Frame

Slower

-

Slower

-

Summary of Contents for Tri-Pack 51

Page 1: ...nd frame must be properly reinforced Adjust closing time speed between 3 and 7 seconds from 90 to 0 These door closers should NOT be installed on the exposed side weather side of exterior doors Right Hand Door RH Left Hand Reverse LHR Left Hand Door LH Right Hand Reverse RHR Right Hand Door RH Left Hand Reverse LHR Right Hand Door RH Left Hand Reverse LHR Regular Arm Installation See Page 2 Left H...

Page 2: ...101 to 120 121 to 180 7 178 6 152 3 1 2 89 Dimension A Door Wall Hardware Jamb conditions permitting Right Hand Shown BC L S L S 51 BF Only Spring Power Adjust If Necessary A B F 90 E D Inches mm 2 PA 2 or 50 Series G Pinion Cap or Optional Cover Caution Don t completely close valve Optional Cover C L Y S Z R L S Stronger Weaker Slower Faster Faster Slower Stronger Weaker ...

Page 3: ... 3 4 197 5 3 4 146 B 7 5 8 194 6 1 8 156 4 1 8 105 C 8 5 8 219 7 1 8 181 5 1 8 130 1 9 1 2 3 4 70 3 8 10 1 2 13 7 16 11 2 50 A 1 1 2 38 7 178 4 102 2 1 8 54 3 1 4 83 1 2 13 3 4 19 9 1 16 230 C L C B Top of Door Door Wall Hardware Jamb conditions permitting Inches mm 5 3 S L Place Arm on Spindle Rotate Remove Arm from Spindle Close Valves L S Latch Sweep Optional Cover See Step 6 on Page 4 Frame Sl...

Page 4: ... Adjust 51 BF only If necessary PA BC S L S L 1 1 2 38 4 or 2 Assemble Arm Arm Screw Open Valves Caution Don t completely close valve Pinion Cap or Optional Cover L Y S Z R L Y S Z R Left Hand Door Right Hand Door or B A Flat Flat Slower Faster Weaker Stronger Stronger Weaker Slower Faster Caution Do Not Back Valve Out Completely ...

Page 5: ...6 152 3 1 2 89 Dimension A Door Wall Hardware Jamb conditions permitting Right Hand Shown BC L S L S 51 BF Only Spring Power Adjust If Necessary 90 Top of Door Inches mm 5 D B A E F PA G Parts Caution Don t completely close valve A longer connecting rod is required for reveals greater than 3 76 or Pinion Cap or Optional Cover Optional Cover Reveal C L Y S Z R Stronger Weaker Slower Faster Faster S...

Page 6: ...10 13 5 7 10 14 16 NOT RECOMMENDED USE 51 18 FULL 360 TURNS MAXIMUM AVAILABLE MAXIMUM DOOR SIZE Number of Turns Required Date Code or or 7 1 2 Stronger 7 1 2 Weaker Use 3 16 Hex Wrench for this Adjustment Use 1 8 Hex Wrench for these Adjustments Stronger Weaker Slower Faster Faster Slower Stronger Weaker 3 6 BE Size Code An ASSA ABLOY Group brand 3000 Highway 74 East Monroe NC 28112 Tel 800 438 19...