The Arm is fitted on the pinion with hex head 
screws.

1

2

3

4

5

Using the templates provided, mark and drill pilot 

holes into the door and frame.

Connect the armset ensuring the pre-loading 

requirement has been completed.

Using the templates provided, fix the mechanism to the door 
as well as the armset and any necessary brackets.

Backcheck Adjustment
To increase the backcheck action, turn the valve clockwise. To decrease, or to turn 
off backcheck , turn the valve counter clockwise.
Adjust the Closing & Latching speed.
1.The door closer can control two different speeds.
2.The No.1 speed-adjusting valve controls  the Closing speed, and the No.2 speed 
   adjusting valve controls the Latching speed.

Operate door closer in order to check operation.

No.2

No.1

No.3

65

°

Fast Slow

No.3 

Backcheck (OPTIONAL)

No.1 Closing

No.2 Latching

Regular Fixing

Installation and Maintenance Instructions:

Maintenance

1.Once the unit has been correctly 

fitted it is recommended that 
periodic checks (every six 
months) are carried out to ensure 
all fixings are tight and the door 
closes freely and positively into 
the frame, without slamming.

2.A light oil lubricant (non-graphite) 

should be applied to the moving 
joints and exposed pivot points.

After Installation

1.When the closer operates to close 

the door from its maximum opening 
position, it should ensure the lock 
latchbolt and any seals are overcome 
and the leaf returned into its frame.

2.When the door is slightly open and 

the latch bolt resting against the 
strike, release the door to ensure the 
leaf fully closes into its frame.

Warning

1.Please note the minimum power size requirement for fire / smoke 

door assemblies is 3 as required by Approved Document B.

2.Do not install mechanical hold open devices on fire / smoke door 

assemblies.

3.Take care not to exceed the maximum opening angle as detailed 

above.

4.Care and attention must be taken when adjusting any of the units 

control valves to avoid damage through over adjustment.

5.All Synergy Door Closer units are sealed for life and the internal 

components assembled under high load, therefore, tampering 
with the mechanism is to be strictly avoided.

Installation Instructions: Please refer to actual size template for exact fitting dimensions 

Fixing in Fig.1 / Fig.61

Pre-Loading of Arm

For the unit to provide the optimum performance and overcome any resistance 
upon closing it is recommended that the armset is “pre-loaded” To pre-load, 
reposition the fixing angle of the arm onto the mechanism so that the end of the 
closing cycle would be past the stop position, as indicated below.

Adjustment Details

After installation check the operation of the door closer. Adjustment to the 

operation of the unit is made by altering the two valves at the front of the 

mechanism. PLEASE NOTE each valve is at its fastest speed with the adjustment 

of 1 full turn.

The following adjustment valves have a maximum adjustment of 1 full turn per 

valve. 

PLEASE NOTE

 over adjustment will damage the mechanism and/or the 

performance of the door closer and invalidate its guarantee.

Adjust the optional Backcheck (valve #3) before adjusting the Closing Speed 

(valve #1) and Latching Action (valve #2).

90°

90°

Before

After

3

Max.

Door width

Max.

Door weight

950mm

60Kg

Power

size

180°
130°

Door opening

Max.

4

1100mm

80Kg

2

180°

850mm

40Kg

ISSUE 05:11/20

10911 ZINS-D975-3S

Fixing Instructions for

S300 Series 

Door Closer 

Power Selectable EN 2-4

www.synergyhardware.co.uk

APPROVED

PRODUCT

CF5294

CPR

AD5193

2812

15

BS EN1154:1997+ A1:2002

3 8 42 1 1 3

90°

www.synergyhardware.co.uk