CAUSE B - TRACTION MOTOR FAULT
PROCEDURE OR ACTION:
1. Measure continuity between the traction motor terminals U and V.
Is continuity present?
YES:
Proceed to Step 2.
NO:
Repair or replace faulty traction motor.
2. Measure continuity between the traction motor terminals U and W.
Is continuity present?
YES:
Proceed to Step 3.
NO:
Repair or replace faulty traction motor.
3. Measure continuity between the traction motor terminals W and V.
Is continuity present?
YES:
Proceed to CAUSE C.
NO:
Repair or replace faulty traction motor.
CAUSE C - FAULTY TRACTION CONTROLLER
PROCEDURE OR ACTION:
1. If no faults are found, replace controller. Make sure to indicate the DTC code(s) on the warranty claim to
include an accurate problem description leading to controller replacement.
END POSSIBLE CAUSES
DIAGRAMS
Traction Motor
END FAULT
Diagnostic Trouble Codes
ELECTRICAL SYSTEM
Check the Service Manual section in Yale Axcess Online for possible updates and check pertinent Bulletins
9030-20-18
Confidential/Proprietary - Do Not Copy or Duplicate
Summary of Contents for MPB045VG
Page 1: ...Maintenance CONTROLLER DIAGNOSTICS MPB045VG A245 PART NO 550095689 9000 YRM 1671 ...
Page 4: ......
Page 6: ......
Page 10: ...9030 4 ...
Page 24: ...NOTES 9030 03 14 ...
Page 83: ......
Page 84: ...9000 YRM 1671 10 19 9 15 1 15 12 14 10 14 4 14 ...