OUR WARNINGS and RECOMMENDATIONS
3.1 If
the
coal used
is the kind to
ignite
difficultly, in
this
case, the type
of
coal having easy ignition
can
be added
on
top of
it.
3.2
Do not
ignite
your Central Heating Stove with flammable and burnable fuels such as benzene, spirit,
gasoline.
3.3 Expansion
tank (Figure 1/12) is open type. Steam outlet (Figure
-
1/13) opening
on
top
must definetely
be open. Please do not close it.
3.4
Do
not operate your Central Heating Stove without water.
3.5
Do not
give water when water boilers
are
heated when
they don't have water inside.
Please wait
till they cool down.
3.6
When
there
is
water
inside the boilers,
do
not
keep
it
waiting when temperature is
zero or
below
zero
degree. Or, please
use
chemicals which prevent freezing. Otherwise, boilers
will be damaged.
3.7
Specially in the regions having much
of lime, "magnetic lime preventer" must
be
connected to the
water
installation
or
to
the inlet of the boiler.
In models with the usage of hot
water,
magnetic lime
preventer
must
be applied bathroom, kitchen hot water inlet
(Figure
-
1/11)in order to prevent the
obstructions of copper serpentine pipes.
FUELS USED
IN
TUKET-Y
AND THEIR
HEATING VALUES
HARD
COAL
ZONGULDAK
SIBERIAN
COAL
LIGNITE,
SOMA,
TAVŞANLI,
TUNÇBİLEK,
DOMANİÇ
LIGNITE
ORHANELİ
BEYPAZARI
ÇAN
SEYİRÖMER
LIGNITE,
ELBİSTAN
KELEŞ
COKE,
Mix
to
Siberian
Coal
with
1/3
rate
COKE,
Mix
with
Lignite
with
1/3
rate
WOOD
Hu=
Hu=
Hu=
Hu=
Hu=
Hu=
Hu=
Hu=
6650-7900
6500-7000
3200-4500
2500-3200
1100-2500
7000-7300
4500-5500
2000-3500
Kcal/h
Kcal/h
Kcal/h
Kcal/h
Kcal/h
Kcal/h
Kcal/h
Kcal/h
HA
6
a
a)
Good Draft
b)
Average
Draft
c)
Bad
DraftÇekiş
Draft
control
of
the Chimney
with Flame
CHIMNEYS and POINTS TO
TAKE
INTO CONSIDERATION
Pipes
of Central
Heating
Stove
must
be as short and they must be in
vertical direction as much as
possible.
Horizontal
pipes must be applied by
having a slight
slope
with the
chimney. Usage of long
horizontal
pipes must be avoided.
Air
and exhaust gas tightness
must
be
provided
for
the
joinings
of
the
pipes with each other.
Figure-9
Attention must be
paid for
chimney
connection.
Pipe's
entry
to
the
chimney
must not
be loose.
•
Fuels which are difficult
to
ignite
must
not
be
placed
in
the stove
while
it is
in
the state of
dying.
Fuel must be added
slowly.
Fuel
must not
be
placed
in
the stove
before
going to
sleep.
Burning
from
the
top
must
be preferred
rather
than trying to
burn from
the
•
bottom.
Prefer
not to set
the fire of your
stove during
low
pressure
weathers
•
of
southwest winds.
Constantly
ventilate the
place where your
Central
Heating Stove
Figure-10
Deeply
applied chimney
•
takes
place.
connection
Chimneys must be
in
compliance with the standards and
they must
be insulated as
well.
•
Chimneys
must
be cleaned on regular basis.
•
In
order
to
prevent
the chimney
to return
the smoke
inside,
it
must
be arranged in a way so
that
its highest
point can be
1
(One)
meter
higher
than the
highest
point of the roof and also a Chimney Cap must be
applied on it.