Burning Condition
Fuel
Type
Re-Fuelling
Interval
Nominal
Slow
6.000 kcal/hour
coal
6.000
kcal/hour
coal
5
hours
12
hours
EXHAUST GAS
TEMPERATURE
Exhaust
Gas
temperature is
200°C average.
2
-
SELECTING THE LOCATION TO PLACE
AND
INSTALLATION INSTRUCTIONS
This device must be mounted
by
being
in
compliance with entire domestic
(national)
legislation
and
related national and European
Standards.
Type
of
Device
YS-02
202
201
Nominal Heat Power
(kw)
26
28
17
Area Heating Power
(kw))
28
28
18
Water Heating Power
(kw)) :
20
20
13.6
Mass
of
the device (kg)
:
120
120
100
Highest
Water Operating Pressure (bar) :
1-2
1-2
1-2
2.1
A
durable tray, capable
of carrying
the weight and heat resistant
for Central
Heating
Stove
must
be
placed
under.
2.2
Distance
of
Central
Heating Stove
from
the wall must be 40 cm. It is
compulsory
to use
open
expansion boiler
2.3 Air Supply: ignition must
be done
from
the top. Entire air
flaps
must
be open during the
first
ignition
and
top
air inlet
(Figure- 7)
must
be closed when coals totally burn.
2.4
Chimney of the device can not be used
together
with another device. Chimney
type
is independent
and it is not suitable for common chimney.
2.5
Top casing (Figure
-
1) must be controlled
once
in
a
month against ash accumulation.
If
needed,
it must also be cleaned
with
the rake.
2.6
Mounting
of
the device to its
place is as stated below.
Summary of Contents for 202
Page 6: ...YS 02 VE 202 KALOR FER TES SATI BA LANTI EMASI ekil 3...
Page 15: ......
Page 21: ...YS 02 and 2020 CENTRAL HEATING INSTALLATION CONNECTION DIAGRAM CD Figure 3...