Set Item 29 [Vacant Memory]
Function:
Display the nunber of vacant Memory Channels in each Memory Bank
(and total vacant Memories in all Banks.)
To do this:
•
After selecting Set Item 29, rotate the
DIAL
knob while pressing
the
[FUNC]
key to display the number of vacant memories.
‚
Press the
[ENT(SET)]
key while pressing the
[FUNC]
key to exit
to normal operation.
Set Item 30 [Copy Channel]
Function:
Copy and paste the desired memory channel
To do this:
•
After selecting Set Item 30, rotate the
DIAL
knob one click clock-
wise while pressing the
[FUNC]
key to enable the Memory Chan-
nel Copy.
‚
Key in the Source Memory Channel number (three digits) from
the keypad, then key in the Destination Memory Channel number
(three digits) from the keypad.
ƒ
Press the
[ENT(SET)]
key while pressing the
[FUNC]
key to exit
to the normal operation.
Set Item 31 [Swap Channels]
Function:
Swap the Memory Channel data between the desired Memories.
To do this:
•
After selecting Set Item 28, rotate the
DIAL
knob one click clock-
wise while pressing the
[FUNC]
key to enable the Memory Chan-
nel Swap.
‚
Key in the two Memory Channel number (each three digit) to be
swapped from the keypad.
ƒ
Memory Channel Swap is now complete.
„
Press the
[ENT(SET)]
key while pressing the
[FUNC]
key to exit
to normal operation.
Set Item 32 [Meter Symbol]
Function:
Select the S meter symbol
Available Values:
n
n
n
/
n
n
n
/
>>>
Default:
n
n
n
Set Mode