14
Trouble Shooting
< Error Messages >
In the case of buzzer sound during the operation, the following massage may display
START
START
E-02 BLADE IS OUT OF POSITION
E-03 MOTOR STOPPED
A signal shows that the blade is not installed correctly or the film is jammed.
・
Turn the POWER SWITCH off.
・
Release FRONT PANEL and SAFETY COVER HOOK, and then, open
SAFETY COVER and check the area of Cutter Blade and Roller.
・
Remove the waste of film and something if you find it.
・
Close FRONT PANEL and SAFETY COVER and fix it.
・
Turn the POWER SWITCH on.
・
A buzzer sounds if pressing START BUTTON and E-02 will display.
Cutter Blade will take an original position if pressing START BUTTON once
again.
・
Reset the film according to film setting.
Indicates that the motor stopped because of an overloaded.
・
Turn the POWER SWITCH off.
・
Open FRONT PANEL and SAFETY COVER.
・
Check the area of FEEDING ROLLER and SUPPORTING ROLLER whether
there is a waste of film.
・
Remove the waste of film in order to avoid scratching any parts if you find it.
・
Close FRONT PANEL and SAFETY COVER.
・
Turn the POWER SWITCH on.
・
Press START BUTTON and make sure that it is properly operated.
・
Reset the film according to film setting.
Do not touch the Blade when you are correcting an error under POWER
SWITCH is on.
If error massage displays again and again or something is wrong with the
machine without error message, please kindly switch off and stop using
immediately.
Blade positions in
readiness
Load the film
Load the film
POWER SWITCH is off
Open the FRONT PANEL and
SAFETY COVER
Inspect around BLADE and
ROLLERS
Remove foreign material
Close the FRONT PANEL and
SAFETY COVER
POWER SWITCH is on
POWER SWITCH is off
Open the FRONT PANEL and
SAFETY COVER
Inspect around BLADE and
ROLLERS
Remove foreign material
Close the FRONT PANEL and
SAFETY COVER
POWER SWITCH is on