There are 5 levels for CLEAN and NEO DYHP Modes, and 3 levels for EYE Mode.
Each time the CLEAN or NEO DYHP button is pressed, the level switches as shown in the below picture.
* There is no level selection available for COOL Mode.
* Use only Level 1 upon the first use and until you are accustomed to use.

 Level Indicator

One short beep will sound to indicate the half-way point in the operation time. 
Refer to pages 9-10 for operation times in each mode.

Level 1

Level 2

Level 3

Level 4

Level 5

 Timer

•  This mode cares for the skin around the eyes using two electrodes on the electrode head.
•  Rotate the electrode head 180° to switch between EYE Mode and Standby Mode. 

The electrode head only rotates in the direction of the arrow shown in the figure 
on the right.

•  The device cannot be operated in Eye Mode if the electrode head is not rotated 180°. 

In addition, the device cannot be used in other modes while the electrode head 
is rotated.

 How to Use EYE Mode

When treatment on a certain mode is completed, two short beeps sound and the device switches to Standby 
Mode (the state in which functioning is suspended). Refer to pages 9-10 for operation times in each mode.
Briefly press the Mode button again to start the selected mode.

 Standby Mode

EYE Mode Electrodes

* *Rotates only as far 

as 180°.

CLEAN/NEO DYHP Mode

EYE Mode

2

Apply skin-care product (gel or lotion) or water on your arm. 
Use the device for approx. 5 minutes in NEO DYHP Mode.

• Do not wet or rub the pre-testing area.

Pre-testing on Skin

* When using the device or a cosmetic product for the first time, always test for compatibility.

1

Clean your skin.

• Wash the inside of your wrist with soap, then wiping it dry with a towel.

If you experience any skin abnormality (redness or burning sensation) at the pre-testing 
area within 24 hours, stop using the device.

ATTENTION

•  Be sure to perform a pre-test in order to prevent skin problems from occurring.
•  If a rash, reddening, itchiness, stinging sensation or other abnormalities occur at the 

pre-testing area, immediately stop the pre-test and wash the area.

•  Check carefully to make sure there is no skin abnormality before using the device. Stop 

using the device immediately if the treatment does not agree with your skin.

Summary of Contents for M30

Page 1: ...Troubleshooting 18 After sales Service 21 Product Specifications 22 Thank you for purchasing this YA MAN product Please read this User s Manual carefully for information on how to use the device prope...

Page 2: ...in COOL Mode Lower eyelids outer corner of the eye except in EYE Mode and COOL Mode Throat Bulging moles Viral warts Areas where you have broken a bone Areas of internal bleeding swelling or scabbing...

Page 3: ...adapter Non intended usesare prohibited Failure to comply may cause a failure of the device or an injury Do not use the device for any purpose or areas other than those stated in the User s Manual Us...

Page 4: ...evice or electronic appliance while the power is on Do not use with other electronic products electric blankets bed sheets heated tables etc at the same time Prohibition If the mode is used for contin...

Page 5: ...ead the display Indicator and Buttons Before Use Before Use Features Names of Components Cotton Stopper Silver Ring AC Adapter The design and specifications of the device and accessories are subject t...

Page 6: ...r at least half an hour after use 1 If using your regular skin care products be sure that they are water soluble Do not use oil based or scrubbing skin care products Failure to comply may cause malfun...

Page 7: ...completed two short beeps sound and the device switches to Standby Mode the state in which functioning is suspended Refer to pages 9 10 for operation times in each mode Briefly press the Mode button a...

Page 8: ...ith the skin every time you use it and keep the device clean at all times Failure to comply may cause skin problems If you feel an unpleasant tingling on your skin reduce the intensity level or move t...

Page 9: ...ime When you hear the beeps begin care on the other side of your face Use the device in a position in which the entire surface of the electrode head comes in contact with your skin Be sure to move the...

Page 10: ...n unit and the wall outlet 2 To clean the device and electrode head wipe them with a damp and well wrung cloth to remove any dirt Wash the cotton stopper with water after removing it from the main uni...

Page 11: ...on The skin lacks moisture or is dry Moisturize your skin with lotion or gel before use You cannot feel the EMS or it feels too weak The treatment temperature is too high except in COOL Mode You canno...

Page 12: ...x D 65 x H 185 mm Main unit with a cotton stopper Approx 230 g Main unit ABS resin Panel Polycarbonate Electrode head PET resin and stainless steel Japan Cotton stopper AC adapter 15 C to 30 C Correct...

Reviews: