7
temperature rises).
key once to finish the temperature correction and the unit
automatically backup mode. The user may continue set other modes or back from
the current setting mode.
Example for temperature correction: The current set temperature value is 200
,
however, the actual temperature is only 190
. So it needs to correct by +10
.
Correction method: if the current correction value is 00 or -00; then change it to
10. If the current correction value is -20, then change it to -10. If the current
correction value is 20, then change it to 30.
5.
Sleep Mode Set
-
and flashes, the unit
enters the Sleep mode status. At this moment, the LED displays the pre-set value.
or
key to change the set value. If set value reads
the unit set in Sleep mode releasing status. If the display read
the unit set in Sleep mode.
key once to finish the sleep mode
setting, then the unit automatically backup. The user may continue set other
modes or back from current set mode.
Please note the manufacturer original design will keep in Free status without
setting Sleep mode.
6.
Wake-up method
Temperature Down Suspend: If the unit set in Sleep mode function, after 20min
idleness, the system will enter the sleep mode automatically, the temperature will
go down to 200
and the LED displays at 200 and flashes
.
Activating the
solder wand will disengage the suspend status and the unit will immediately ramp
up to the preset temperature. There are three methods of wake-up the Temperature
Down Suspend.
a. Pick up the solder wand.
b. Press any key of the unit.
c. Turn off the main switch and restart.
Power off Suspend: If the unit enters the Sleep mode over 40min without wake-up,
the unit will enter automatically the power off suspend status. It means the heater
power will be cut off and the LED displays
and flashes. The only way
to awake the power cut off mode is to switch off the main power and re