RS-1600-FC-FFX2 User Guide
32
2.9
Drive Carrier Configuration
2.9.1 Planning and Configuring Your Installation
2.9.1.1
System Configuration
Important
Before you begin installation you should become familiar with the configuration requirements of
your RS-1600-FC-FFX2 system. Please refer to Section
2.2
for information on your overall system
configurations.
There must be a drive present in Bay 1/1 or 4/4 to enable SES Communications to operate.
Installing drives in both of these bays will provide redundant SES communication paths.
When planning your system configuration, please remember that all RS-1600-FC-FFX2 enclosure drive
bays must be filled with either a drive carrier or front dummy fascia, no bays should be left completely
empty.
2.9.1.2
Drive Configuration
Important
After you have installed the drive carrier modules in your RS-1600-FC-FFX2 enclosure, please
refer to Section
2.5
for configuration information relevant to the I/O module you are installing.
2.10 Drive Carrier Installation
2.10.1 Parts Check List
• Drive Carrier module or
• Dummy Carrier module
2.10.2 Procedure
Important
For a Rack Mounted System: Ensure that the carrier is orientated so that the drive is uppermost
and the handle opens from the left. (
Figure 2–15
).
For a Tower System: Ensure that the carrier is orientated so that the carrier lock position is
uppermost and the handle opens from the top
1
Release the carrier handle, by pressing the latch in the handle towards the right and insert the carrier into
the enclosure.