RS-1600-FC-FFX2 User Guide
12
1.3.5 Dummy Carrier Modules
Dummy carrier modules are provided for fitting in all unused drive bays. They are designed as integral
drive module front caps with handles and must be fitted to all unused drive bays to maintain a balanced
airflow.
Warning
Operation of the Enclosure with ANY modules missing will disrupt the airflow and the drives will
not receive sufficient cooling. It is ESSENTIAL that all apertures are filled before operating the
unit. Dummy Carriers are available for this purpose.
1.4 Visible and Audible Alarms
The functional modules have associated status LEDs. The Ops Panel shows a consolidated status for all
modules.
LEDs show constant green for good or positive indication. Constant Amber LEDs indicate there is a fault
present within that module.
The Ops Panel also incorporates an Audible Alarm to indicate when a fault state is present and also an
Alarm Mute push-button.
Warning
The Ops Panel is an integral part of the enclosure chassis assembly and can only be replaced by
trained personnel.
1.5 RS-1600-FC-FFX2 Technical
Specification
1.5.1 Dimensions
Rack Enclosure
Height 134mm, Width 446mm, Depth 580mm
Tower Enclosure
Height 501mm, Width 230mm (including mounting feet), Depth 580mm
Note
It is recommended that a rack with a depth of no less than 700mm is used with this product.
1.5.2 Weight
Maximum Configuration
Rack mount:
Tower:
37kg (81lb)
40kg (88lb)
Empty Enclosure (Rack)
9kg (19.8lb)
PSU/Cooling Module
4kg (8.8lb)
LRC I/O Module
1.5kg (3.11lb.)
Tower Conversion Kit
3kg (6.6lb)