1. Supplied Material

Each package contains:

•  1 iPERL device in resp. frequency:

  - 169 MHz / 500 mW;

  - 433 MHz / 10 mW or

  - 868 MHz / 25 mW

• manual

•  optional connection kits

•  NRV with gasket (if ordered)

2. General Instructions

Please read this guide prior to installing iPERL.

iPERL is a metering endpoint designed for use with potable water supplies 

to residential, commercial and industrial activities.

iPERL is intended for maintenance-free operation for up to 15 years. 

IPERL is hermetically sealed and therefore there is no servicing of the 

meter required. The water meter is designed for use with potable water for 

residential activities. The meters must be stored in a dry, cool place, free of 

contamination. Please make sure that

during installation all hygienic standards and recommendations are 

respected.

3. Permissible Operating Conditions

•  min. water conductivity required:  120µS/cm (25 °C)

•  Cold and warm water meter: from 0.1 °C up to 50 °C (70 °C, special 

variant)

•  Pressure stage: MAP16bar

•  Mechanical environment: M2 (MID) 

fixed installation with minimum vibration

•  Electromagnetic environmental class: E1 and E2 (MID) residential and 

commercial

•  Protection class: IP68

•  Climatic environment: from -15 °C up to 60 °C

4. Installation Requirements

Ensure that the pipework does not introduce mechanical stresses on the 

meter body: checking both alignment of the pipework with the threaded 

connections and distance between unions with the meter lay length. If 

there is mechanical stress usage of the brackets is recommended. When 

mounting iPERL onto a network, ensure contact surfaces are even and 

clean and use new gaskets.

At all times during installation and thereafter all statutory provisions, 

regulations and norms have to be followed, in particular with regard to 

health and safety (e.g. earthing, bridging, etc.). Composite materials used 

are nonconductive.

Torque: tighten iPERL to a minimum torque setting of 20Nm and a maximum 

of 30Nm. 

Ensure the metallic water service plumbing is properly grounded per 

electrical codes. If installing indoors, install an electrical grounding strap for 

safety.

Installation position: iPERL has been designed to operate, with no impact 

on metrological performance, in all installation angles and orientations.

Note: When flow direction arrow is pre-set, it needs to be respected.

Please avoid installing iPERL as shown below as a reduction of battery 

lifetime could occur.

Keep the valves closed when the premises are vacant. Make sure you close 

both valves before and after the meter for safety reasons when installation 

is not finished yet or there is no water consumption for a longer period, e.g 

due to vacant premises.

iPERL is free of any constraint for upstream or downstream straight pipe 

lengths.

Flow  direction:  iPERL’s  metrological  performance  is  independent  of  flow 

direction and orientation of the meter can be selected to best suit the 

installation conditions. iPERL will detect flow direction when installed and 

set the direction indicator accordingly.

Pressure: please ensure that iPERL strictly operates within the pressure 

rating printed on the meter body.

All iPERL settings and functions will be automatically and correctly activated 

once the flowtube is saturated. 

5. Installation Procedure (Volume registration & Flow direction)

STEP1:

1A:

 Remove iPERL from its packaging and locate any optional component 

(filter, non-return-valve

1)

 (NRV), ...)

In case you need a non-return-valve please consider:

3

 iPERL, DN 15, 110 and 115 mm: NRV installation in meter screw 

connection of meter outlet (no gasket required)

All other nominal sizes and lengths: NRV installation in the outlet of the 

measuring tube using the gasket provided in the delivery.

If you do not use a NRV you can choose any other gasket.

iPERL will display the following symbols:

No Volume, no flow 

2)

 and the alarm flag (raised for empty pipe)

1B:

 Install iPERL according to the most suitable LCD orientation

STEP2:

Once installed, open the upstream valve to fill the meter. The alarm flag 

disappears after a short while, this indicates that the meter has detected 

water in the pipe.

iPERL is now fully operational, although in stand-by mode. At this point, also 

the  radio  transmission  is  activated  which  is  indicated  by  a  flashing  radio 

symbol. The meter starts to send out radio telegrams. 

STEP3:

7A

 To activate the “flow direction arrow”, ensure a flow above the threshold 

of  

 

3  l/h  for  DN 15

 

5  l/h  for  DN 20

 

8  l/h  for  DN 25

  12.5  l/h  for  DN 32

  20  l/h  for  DN 40

Both arrows blink to indicate the meter is detecting its forward flow direction. 

After reaching the threshold the arrow is set. 

It starts to accumulate volume into the three registers  forward, reverse and 

billing volume. The flowrate will start to be displayed after the first 4 hours 

of operation.

When the billing volume register reaches the threshold of 

  25 l  for  DN 15

  40 l  for  DN 20

  63 l  for  DN 25 - 40

the meter takes that register with the higher volume accumulated as the 

forward register and fixes the flow direction.

From this moment on the flow direction cannot be changed; any flow in the 

'wrong' direction will now trigger the alarm flag for 'reverse flow' and will be 

counted as reverse  volume.

7B 

When  flow  direction  arrow  is  pre-set,  it  will  appear  immediately  on 

the LCD. For the first 4 hours of initial operation the flow rate indication is 

in setup process and the displayed value is only informative. The actual 

flow rate will be displayed after 4 hours of operation.The volume counting 

operation is not affected as this is independent from the flow information 

shown on the display.

After  the  flow  direction  is  set,  the  functions  for  performing  the  higher 

analysis, such as data logging and leak detection, become active and are 

assigned to the respective data fields.

IMPORTANT! iPERL does not register the volume if the averaged flowrate 

is below:

iPERL 433 & 868 MHz

iPERL 169 MHz

1.6 l/h for DN 15

1 l/h for DN 15

2.5  l/h for DN 20

1.6 l/h for DN 20

4.0  l/h for DN 25

DN25 out of scope                               

6.4  l/h for DN 32

4 l/h for DN 32

10.0  l/h for DN 40

6.4 l/h for DN 40

6. iPERL Display and Characters

10 

After installation is successfully completed the display shows:

• Meter reading and preselected unit

• Current flowrate and preselected unit

• Flow direction

• RF active

11 

After the LCD self-test the firmware version will be shown followed by 

the alarms:

Alarm

iPERL 433 & 868 MHz

iPERL 169 MHz

AL – 05

Empty pipe

AL – 06

Magnetic tampering

Magnetic tampering (if AL 06 

is present also LED will blink)

AL – 07

Reverse Flow

AL – 08

Broken pipe / Leakage

Damage Alarm

If any of the following graphics is displayed, please contact your supplier:

• Alarm flag + AL-xx (except 05-08, see above)

• Low battery warning

• Test mode

Note: The red lines printed on the display (last 3 digits after the comma) 

show the liters and shall help read the display more easily.

7. Disposal

12 

This product contains a lithium Ion battery. In the interest of protecting the 

environment, this battery may not be disposed in household waste after its 

period of use. The local and national regulations for environmental protection 

are to be considered. The expected lifetime of the battery is shown on the 

battery pictogram lasered on the iPERL, e.g. 1241 = Month 12 (December), 

Year 41 (2041). The meter should be removed or replaced until this date as 

the battery is encapsulated and cannot be removed separately.

1) Australia only: NRV is already pre-installed!

2) "no flow" sig

nal        on display not available in Chile

Installation Manual

1

12

Graphic

Description

Meter Reading

Current flowrate

Index units

Flowrate units

Alarm flag

Flow direction

RF active

Low battery warning

Test mode

2

8

1241

Lithium

5

3

4

iPERL

6

9

8

7

10

5

2)

11

EN DE

FR

ES

IT

SI

Summary of Contents for Sensus iPERL

Page 1: ...Installation Manual Einbau und Betriebsanweisung Manuel d Installation Manual de Instalaci n Manuale per l installazione Navodila za vgradnjo in uporabo...

Page 2: ...her gasket iPERL will display the following symbols 5 No Volume no flow 2 and the alarm flag raised for empty pipe 1B Install iPERL according to the most suitable LCD orientation STEP2 6 Once installe...

Page 3: ...montiert Wenn Sie keinen R ckflussverhinderer verwenden k nnen Sie eine beliebige Dichtung verwenden Folgende Symbole werden angezeigt 5 Kein Volumen kein Durchfluss 2 und Alarmflagge bei leerer Rohr...

Page 4: ...ir sch ma Joint non necessaire 4 Pour tous les autres diam tres et longueurs Installation du clapet anti retour dans la tubulure de sortie en utilisant le joint fourni avec le compteur Si vous n utili...

Page 5: ...de alarma activado por tuber a vac a 1B Instalar iPERL seg n la orientaci n m s adecuada para la pantalla LCD PASO 2 6 Una vez instalado abrir la v lvula aguas arriba para llenar el sensor de medida...

Page 6: ...ndezze nominali e lunghezze Installazione NRV nell uscita del tubo di misura utilizzando la guarnizione fornita alla consegna Se non si utilizza una NRV possibile scegliere qualsiasi altra guarnizione...

Page 7: ...gradnji protipovratnega ventila uporabiti prilo eno tesnilo e protipovratnega ventila ne boste vgradili lahko uporabite standardna tesnila Ko iPERL vzamete iz katle so na zaslonu prikazani Slika 5 Por...

Page 8: ...www sensus com info int xyleminc com Declaration of conformity Konformit tserkl rung D claration de conformit EN DE FR ES IT SI iPERL...

Page 9: ...www sensus com info int xyleminc com Declaraci n de conformidad Dichiarazione di Conformita Izjava EU o skladnosti EN DE FR ES IT SI iPERL...