7

Display

The display is a passive LCD.

The display is set in fixed mode with the following automatic display cycle:

For the initial 60 seconds, the Main view displays;

For the following 12 seconds, the Periodic readings display;

For the following 12 seconds, the Display Test and firmware version.

Display icons

Icons

Description

Test

: Activated during test mode.

Error

: Activated when an error is detected.

Transmission antenna

: Signals radio transmission or radio enabled.

Calendar

: Activated when billing dates display.

Battery

: Activated when the calculated service life is coming to an end or when the voltage drops below the 

minimum value (in which case the error icon also displays).

Leakage

: Activated when the leakage alarm is triggered.

Back flow

: Activated when the reverse flow alarm is triggered.

Star indicator

: The indicator, consisting of 2 arc segments, follows the flow by rotating clockwise for direct 

flow and anticlockwise for reverse flow.

Main view

The display cycle is automatically repeated 4 times, for a total of 60 seconds.
The Volume measured displays for 12 seconds and is expressed in m

3

. The value displays the decimal point for litres, 

therefore 5 digits for m

3

 and 3 digits for litres. The presence of a flow and its direction is displayed by the star indicator.

Range displays for 3 seconds and the value always displayed is expressed in m

3

/h to 3 decimal places. If no flow is 

detected, the value displayed is 0. The presence of a flow and its direction is displayed by the star indicator.

Periodic readings

Following an automatic sequence, billing date references display:

Billing date 1: displays the date for 3 seconds (for example, 12.05.21 indicates 12 May 2021);

Billing value 1: displays the volume recorded on the billing date for 3 seconds;

Billing date 2: displays the date for 3 seconds (for example, 02.09.21 indicates 2 September 2021);

Billing value 2: displays the volume recorded on the billing date for 3 seconds.

Summary of Contents for sensus DomoJet R

Page 1: ...DomoJet R USER GUIDE MA 1030 INT 0002 10 2022...

Page 2: ...fety warnings 3 Restrictions 4 Construction 5 Battery 6 Display 7 Technical specifications 8 2 Install the DomoJet R 10 Seals 11 Use 12 Program the radio 12 Error codes 12 Test mode 12 Care and mainte...

Page 3: ...ode can be scanned with any suitable device such as a smartphone using a QR application The internet link leads to the website with the token The actual key is accessible through this website after su...

Page 4: ...e and knowledge unless supervised by a person responsible for their safety and following adequate training in how to use the product The product may only be used in accordance with the corresponding l...

Page 5: ...5 Construction Structure Dimensions 1 Register counter 2 Display 3 Meter housing 4 Colored water temperature indicator...

Page 6: ...ntense heat may damage the battery and reduce its lifespan The meter calculates the useful remaining life of the battery based on memorized parameters for example estimated consumption of the electron...

Page 7: ...flow by rotating clockwise for direct flow and anticlockwise for reverse flow Main view The display cycle is automatically repeated 4 times for a total of 60 seconds The Volume measured displays for 1...

Page 8: ...mal using both digits and letters 09 AF Any error codes for 3 seconds e g Err XXXX where XXXX is the hexadecimal code for the error See table Error codes Technical specifications Meter specifications...

Page 9: ...evice specifications Features Description Environmental class O Mechanical class M1 Electronic class E2 Temperature range for storage from 10 C to 60 C Ambient temperature range from 25 C to 55 C Pres...

Page 10: ...an 100 litres Meter blocked no consumption for at least 30 days Reversed meter reverse flow lasts for more than 10 days 2 Install the DomoJet R Follow these steps to install the meter Warning Installa...

Page 11: ...ion of the arrow on the meter coincides with the flow direction Install proper interception valves upstream and downstream from the meter to permit maintenance operations and inspections on the meter...

Page 12: ...cturer Error codes The error code is displayed in hexadecimal format The instrument identifies 5 errors which may also occur simultaneously Hexadecimal format Description 0080 Out Of Operating Tempera...

Page 13: ...cannot be disposed of as domestic waste The device does not contain any toxic hazardous substances or elements including lead mercury cadmium hexavalent chromium polybrominated biphenyl It therefore c...

Page 14: ...14 Appendix A EU Declaration of Conformity The following is the EU Declaration of Conformity from Maddalena...

Page 15: ...15...

Page 16: ...ading portfolio of smart metering network technologies and advanced analytics solutions for water electric and gas utilities In more than 150 countries we have strong long standing relationships with...

Reviews: