12
by a centre authorized by the manufacturer.
Use
DomoJet R is ideal for both cold and hot water residential use where compactness, flexibility and the availability of an
integrated radio reading make the difference.
Program the radio
DomoJet R is supplied with factory-set setup data. The radio is activated after the passage of 100 liters of water, but can
also be activated by placing a magnetic key in the appropriate symbol.
The radio settings, such as the type of radio frame and data transmission frequency, have a default factory setting.
You may change radio settings after radio activation using the appropriate programming kit. For further information,
contact the manufacturer.
Error codes
The error code is displayed in hexadecimal format.
The instrument identifies 5 errors which may also occur simultaneously.
Hexadecimal format
Description
0080
Out Of Operating Temperature
0400
Low Battery Voltage
1000
Metrological verification period expired
4000
Metrological Wrong Checksum
Simultaneous errors are combined. For example; Low battery v Metrological verification period expired = Error
1400.
Test mode
DomoJet R can be temporarily set to a high resolution in order to perform measurement tests. Contact the
manufacturer for further information.
Care and maintenance
No particular cleaning procedures are required. However, the installation area should be kept clean and periodic
checks should be performed to ensure the required environmental conditions are met.
Restriction
: Use of abrasive products, gasoline, or trichloroethylene is prohibited.