11

instead of the meter.

2.  If there is no water in the tube before installing the meter, open the valve upstream from the meter. This is 

necessary because the valve can cause air suction at the end of installation which could damage the meter.

3.  Before using the meter, first fully remove air from the pipe and the meter itself. The interception/ adjustment valves 

must be fully open when doing this. Open the valve at the start first and then open the valve at the end.

4.  When replacing the meter, it is recommended to replace the gasket on the fitting. Recommended gasket hardness: 

minimum 80 Shore A. Tighten the nut with a torque wrench and use a counter wrench to hold the meter in position. 
Maximum tightening torque: 40 Nm. Before positioning the seal, make sure that:

The seal is not damaged during installation.

The level of the seal is level with the tubing.

The seal does not protrude from the tube.

The surfaces of the flange are clean and undamaged.

5.  Install the meter in a position that is protected from freezing (insulate it if necessary with insulation material) and in 

the lower part of the system to prevent air accumulation.

6.  Use the following guidelines to ensure correct installation:

Install the meter in a position protected from blows and tampering, where readings are easy to make.

Install the meter so that the direction of the arrow on the meter coincides with the flow direction.

Install proper interception valves upstream and downstream from the meter to permit maintenance operations and 

inspections on the meter, as well as to check the system.

The installation of a non-return valve inside or outside the meter is also recommended (see dedicated data sheet).

7.  Check the seal hold to prevent leakage.

Follow these guidelines during installation:

Installation position

Observe the indications on the dial (letters H and V):

H: the meter must be installed with the dial in a horizontal position.

V: the meter must be installed with the dial in a vertical position.

H and V: the meter may be installed with the dial in either a horizontal or vertical position.

Avoid vertical installations with downward flow, or with the dial facing downwards.

Allowable water pressure (ISO 4064-1)

The maximum allowable pressure (MAP) is 16 bar, and is displayed on the meter dial. If not indicated on the dial, it must 
be 10 bar. These values must never be exceeded. The maximum allowable pressure (MAP) downstream of the meter 
must be greater than or equal to 30 kPa (0,3 bar).

Commissioning

Before putting the meter into operation, completely vent the air from both the pipe and the meter itself (rotate it if 
necessary). The interception/adjustment valves must be fully open when doing this. Open the valve at the start first and 
then the valve at the end.

Seals

A seal is applied to the meter: it cannot be opened without breaking it. Any intervention must therefore be carried out 

Summary of Contents for sensus DomoJet R

Page 1: ...DomoJet R USER GUIDE MA 1030 INT 0002 10 2022...

Page 2: ...fety warnings 3 Restrictions 4 Construction 5 Battery 6 Display 7 Technical specifications 8 2 Install the DomoJet R 10 Seals 11 Use 12 Program the radio 12 Error codes 12 Test mode 12 Care and mainte...

Page 3: ...ode can be scanned with any suitable device such as a smartphone using a QR application The internet link leads to the website with the token The actual key is accessible through this website after su...

Page 4: ...e and knowledge unless supervised by a person responsible for their safety and following adequate training in how to use the product The product may only be used in accordance with the corresponding l...

Page 5: ...5 Construction Structure Dimensions 1 Register counter 2 Display 3 Meter housing 4 Colored water temperature indicator...

Page 6: ...ntense heat may damage the battery and reduce its lifespan The meter calculates the useful remaining life of the battery based on memorized parameters for example estimated consumption of the electron...

Page 7: ...flow by rotating clockwise for direct flow and anticlockwise for reverse flow Main view The display cycle is automatically repeated 4 times for a total of 60 seconds The Volume measured displays for 1...

Page 8: ...mal using both digits and letters 09 AF Any error codes for 3 seconds e g Err XXXX where XXXX is the hexadecimal code for the error See table Error codes Technical specifications Meter specifications...

Page 9: ...evice specifications Features Description Environmental class O Mechanical class M1 Electronic class E2 Temperature range for storage from 10 C to 60 C Ambient temperature range from 25 C to 55 C Pres...

Page 10: ...an 100 litres Meter blocked no consumption for at least 30 days Reversed meter reverse flow lasts for more than 10 days 2 Install the DomoJet R Follow these steps to install the meter Warning Installa...

Page 11: ...ion of the arrow on the meter coincides with the flow direction Install proper interception valves upstream and downstream from the meter to permit maintenance operations and inspections on the meter...

Page 12: ...cturer Error codes The error code is displayed in hexadecimal format The instrument identifies 5 errors which may also occur simultaneously Hexadecimal format Description 0080 Out Of Operating Tempera...

Page 13: ...cannot be disposed of as domestic waste The device does not contain any toxic hazardous substances or elements including lead mercury cadmium hexavalent chromium polybrominated biphenyl It therefore c...

Page 14: ...14 Appendix A EU Declaration of Conformity The following is the EU Declaration of Conformity from Maddalena...

Page 15: ...15...

Page 16: ...ading portfolio of smart metering network technologies and advanced analytics solutions for water electric and gas utilities In more than 150 countries we have strong long standing relationships with...

Reviews: