1. General information

Please read these instructions carefully and fully before you start installing the meter. Follow all the safety and warning instructions to avoid per-
sonal injury and damage to the meter and the overall installation. Before installing the meter, make sure the delivery is complete and free from 
damage.

Intended use

Cordonel meters may only be used for the applications specified in the data sheet and in these operating instructions. Correct and safe use of 
the products requires proper transportation, storage, installation, commissioning and operation. The permissible ambient conditions must be 
observed at all times. The notes given in these instructions must be followed fully.

Exclusion of liability

The contents of these operating instructions have been checked thoroughly for compliance with the hardware and software described. Neverthe-
less, minor deviations cannot be ruled out due to continuous improvements, meaning Sensus shall assume no liability whatsoever for full compli-
ance. The information in these instructions is checked regularly and any corrections are included in the next edition.

2. Product description

Cordonel is a static bulk water meter for industrial and commercial applications. The meter uses ultrasonic technology based on the transit time 
method. The meter is equipped with three ultrasonic paths, which are arranged in pairs and alternately send and receive ultrasonic signals with 
and against the direction of flow of the water. The time the signal takes to go from the transmitter to the receiver is measured. The flow velocity is 
calculated using the differing transit time of the signal with and against the flow. The flow volume is calculated by multiplying the flow velocity by 
the constant cross-section of the measuring tube.

3. Uses

- For measuring potable water up to 50 °C
- For measuring clean process water up to 50 °C
- For measuring water in field irrigation systems
- For controlling industrial processes using the pulse output

4. Scope of delivery

1 water meter, 2 flange gaskets, 1 operating instructions

5. Technical data

Nominal widths

DN 40 … 300

Pressure stage

PN10; PN16

Connections

Flanges according to EN1092-2

Medium

Water; chemically neutral

Metrological approval

DE-19-MI001-PTB008

Potable water approvals

KTW, DVGW, WRAS, ACS, KIWA

Medium temperature range

0.1… 70 °C for industrial applications
0.1 … 50 °C for commercial applications

Ambient temperature during storage and transportation

Normal conditions: -10 °C ... 40 °C
for one week: -40 °C ... 60 °C 

Ambient temperature during use

-10 °C … 70 °C (medium must never freeze)

Accuracy class

Class 2

Protection class

IP X8 acc. to DIN EN 60529:2014

Mechanical environmental conditions

Class M2

Electromagnetic environmental conditions

Class E2

Pulse output (optional)

External module; galvanically isolated

Battery

2x type D lithium battery

Display

LCD; 2 rows with symbols
Display line 1: 9 digits
Display line 2: 4 digits

Radio frequency

433 MHz or 868 MHz

Transmitting power

433 MHz: 10 mW
868 MHz: 25 mW

 

Cordonel

Page 3

Summary of Contents for Sensus Cordonel DN 100

Page 1: ...Cordonel Static Flow Meter Installation and Operating Instructions...

Page 2: ...Commissioning 5 8 7 Operation notes 5 9 Reading 5 9 1 Display description 5 9 2 Display sequence 6 9 3 Alarms 6 9 4 Testing mode 7 10 Data logger 7 11 Radio 8 11 1 General 8 11 2 SensusRF 8 11 3 wM Bu...

Page 3: ...receive ultrasonic signals with and against the direction of flow of the water The time the signal takes to go from the transmitter to the receiver is measured The flow velocity is calculated using th...

Page 4: ...O 4064 5 2014 The meters are disinfected after the production process Handling during installation must be carried out in accordance with applicable hygiene rules We refer in particular to VDI DVGW Gu...

Page 5: ...iring in the direction of flow upstream of the meter Use suitable measures to protect the meter against water hammers in the pipe Do not carry out welding work on the pipe with the meter installed to...

Page 6: ...rm flag and alarm code Alarm Code Description Comment ALr 001 Low battery alarm Appears when the remaining battery life is approx six months ALr 004 Empty pipe alarm Appears when the measuring pipe is...

Page 7: ...adio command The testing mode is terminated automatically after 72 hours at the latest The time of the automatic termination of the testing mode can be set using the Diavaso config app Switching to te...

Page 8: ...5 seconds After every fourth BUP the meter listens for a short period LAT as to whether further information is requested If a radio com mand PAM is received during this period the meter sends the corr...

Page 9: ...saved meter reading Volume unit Time that data was last saved 13 Factory settings Values Unit DN 40 DN 50 DN 65 DN 80 DN 100 Leakage duration Days 14 Leakage threshold value m h 0 25 0 375 0 625 0 875...

Page 10: ...e Off Key date value net volume On Key date value alarm status On Wake up interval Sec 3 UTC time shift Hours 0 Pulse On Pulse mode A4 balanced pulse Pulse value Litres 100 Pulse length ms 500 1 The i...

Page 11: ...bserve section 8 2 18 Transportation The meters should be transported dry as frost free as possible and under hygienically harmless conditions If possible the meters should always be transported in th...

Page 12: ...ity Cordonel Page 12 Sensus GmbH Hannover Meineckestra e 10 30880 Laatzen T 49 0 5102 74 0 F 49 0 5102 74 3341 Email info int xylem com www sensus com MB 2000 INT Version 0004 May 2021 Subject to chan...

Reviews: