background image

Values

Unit

DN 40

DN 50

DN 65

DN 80

DN 100

Data logger reverse volume

Off

Data logger net volume

On

Data logger alarm status

On

Readout on … day of month

Day:

1

Key date value of forward volume

Off

Key date value time minimum flow rate

Off

Key date value minimum flow rate

Off

Key date value time pipe burst

Off

Key date value pipe burst

Off

Key date value instantaneous flow rate 1

Off

Key date value time peak flow rate 2

Off

Key date value peak flow rate 2

Off

Key date value time maximum flow rate 3

Off

Key date value maximum flow rate 3

Off

Key date value minimum pressure

Off

Key date value time minimum pressure

Off

Key date value maximum pressure

Off

Key date value time maximum pressure

Off

Key date value minimum temperature

Off

Key date value time maximum temperature

Off

Key date value maximum temperature

Off

Key date value time maximum temperature

Off

Key date value current pressure

Off

Key date value current temperature

Off

Key date value extended alarms

Off

Key date value reverse volume

Off

Key date value net volume

On

Key date value alarm status

On

Wake up interval

Sec.

3

UTC time shift

Hours

0

Pulse

On

Pulse mode

A4 balanced pulse

Pulse value

Litres

100

Pulse length

ms

500

 
1) The instantaneous flow rate is the mean value of the logger period
2) The peak flow rate is the mean value over 2 seconds
3) For maximum flow rate, see section10

14. Temperature measurement

The Cordonel measures the water temperature. The measurement is performed directly by the ultrasonic signal. The measured temperature is 
shown on the display in line 2 and can be transmitted by radio via the SEMI data protocol of SensusRF.

15. Optional pulse output

The Cordonel is equipped with a slot for a pulse adapter.

If the Cordonel is delivered without a pulse module, the slot is fitted with a dummy to protect it against contamination.

The dummy must be removed before installing the pulse module. When doing so, make sure dirt does not enter the slot. If the slot is dirty, it must 
be cleaned carefully by rinsing and wiping it with a soft cloth. Avoid scratching the surface.

If the pulse module has been installed, the cable must be routed directly from the Cordonel meter towards the bottom of the meter. 
 

Cordonel

Page 10

Summary of Contents for Sensus Cordonel DN 100

Page 1: ...Cordonel Static Flow Meter Installation and Operating Instructions...

Page 2: ...Commissioning 5 8 7 Operation notes 5 9 Reading 5 9 1 Display description 5 9 2 Display sequence 6 9 3 Alarms 6 9 4 Testing mode 7 10 Data logger 7 11 Radio 8 11 1 General 8 11 2 SensusRF 8 11 3 wM Bu...

Page 3: ...receive ultrasonic signals with and against the direction of flow of the water The time the signal takes to go from the transmitter to the receiver is measured The flow velocity is calculated using th...

Page 4: ...O 4064 5 2014 The meters are disinfected after the production process Handling during installation must be carried out in accordance with applicable hygiene rules We refer in particular to VDI DVGW Gu...

Page 5: ...iring in the direction of flow upstream of the meter Use suitable measures to protect the meter against water hammers in the pipe Do not carry out welding work on the pipe with the meter installed to...

Page 6: ...rm flag and alarm code Alarm Code Description Comment ALr 001 Low battery alarm Appears when the remaining battery life is approx six months ALr 004 Empty pipe alarm Appears when the measuring pipe is...

Page 7: ...adio command The testing mode is terminated automatically after 72 hours at the latest The time of the automatic termination of the testing mode can be set using the Diavaso config app Switching to te...

Page 8: ...5 seconds After every fourth BUP the meter listens for a short period LAT as to whether further information is requested If a radio com mand PAM is received during this period the meter sends the corr...

Page 9: ...saved meter reading Volume unit Time that data was last saved 13 Factory settings Values Unit DN 40 DN 50 DN 65 DN 80 DN 100 Leakage duration Days 14 Leakage threshold value m h 0 25 0 375 0 625 0 875...

Page 10: ...e Off Key date value net volume On Key date value alarm status On Wake up interval Sec 3 UTC time shift Hours 0 Pulse On Pulse mode A4 balanced pulse Pulse value Litres 100 Pulse length ms 500 1 The i...

Page 11: ...bserve section 8 2 18 Transportation The meters should be transported dry as frost free as possible and under hygienically harmless conditions If possible the meters should always be transported in th...

Page 12: ...ity Cordonel Page 12 Sensus GmbH Hannover Meineckestra e 10 30880 Laatzen T 49 0 5102 74 0 F 49 0 5102 74 3341 Email info int xylem com www sensus com MB 2000 INT Version 0004 May 2021 Subject to chan...

Reviews: