SAFETY INSTRUCTIONS                  

TO AVOID SERIOUS OR FATAL PERSONAL 

INJURY OR MAJOR PROPERTY DAMAGE, READ 

AND FOLLOW ALL SAFETY INSTRUCTIONS IN 

MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE 

INSTALLATION AND OPERATION OF THIS UNIT 

AND MUST BE KEPT WITH THE PUMP.

This is a 

SAFETY ALERT SYMBOL

When you see this symbol on the 

pump or in the manual, look for one 

of the following signal words and 

be alert to the potential for personal 

injury or property damage.
Warns of hazards that 

WILL

 cause 

serious personal injury, death or major 

property damage.
Warns of hazards that 

CAN

 cause 

serious personal injury, death or major 

property damage.
Warns of hazards that 

CAN

 cause  

personal injury or property damage.

 NOTICE:  INDICATES SPECIAL INSTRUCTIONS  

 WHICH ARE VERY IMPORTANT AND  

 MUST BE FOLLOWED.

THOROUGHLY REVIEW ALL INSTRUCTIONS 

AND WARNINGS PRIOR TO PERFORMING ANY 

WORK ON THIS PUMP.

ALL PLUMBING AND ELECTRICAL 

WORK MUST BE PERFORMED 

BY A QUALIFIED TECHNICIAN 

IN COMPLIANCE WITH THE 

INSTALLATION REGULATIONS IN 

FORCE.

MAINTAIN ALL SAFETY DECALS.

THE PUMP MUST BE LIFTED AND HANDLED 

WITH CARE.

READ MANUAL CAREFULLY BEFORE 

PROCEEDING.

UNIT NOT DESIGNED FOR USE 

WITH HAZARDOUS LIQUIDS OR 

FLAMMABLE GASES. THESE  

FLUIDS MAY BE PRESENT IN  

CONTAINMENT AREAS.

CAUTION: Hot Surface Hazard

 The outer surfaces of the pump and   

motor can exceed 104ºF (40ºC) if hot liquids 

are being pumped. Do not touch with any 

part of the body without protective gear.

• Do not put any combustible material near 

the pump.

DESCRIPTION & SPECIFICATIONS:

The Models NPE (close-coupled) and NPE-F (frame-

mounted) are end suction, single stage centrifugal 

pumps for general liquid transfer service, booster ap-

plications, etc. Liquid-end construction is all AISI Type 

316 stainless steel, stamped and welded. Impellers are 

fully enclosed, non-trimable to intermediate diameters. 

Casings are fitted with a diffuser for efficiency and for 

negligible radial shaft loading. 
Close-coupled units have NEMA 48J or 56J motors 

with C-face mounting and threaded shaft extension. 

Frame-mounted units can be coupled to motors 

through a spacer coupling, or belt driven.

1. IMPORTANT:

1.1.

 Inspect unit for damage. Report any damage to 

carrier/dealer immediately.

1.2.

 Electrical supply must be a separate branch circuit 

with fuses or circuit breakers, wire sizes, etc., per 

national and local electrical codes. Install an all-leg 

disconnect switch near pump.

Always disconnect electrical power 

when handling pump or controls.

1.3.

 Motors must be wired for proper voltage. Motor 

wiring diagram is on motor nameplate. Wire size 

must limit maximum voltage drop to 10% of  

nameplate voltage at motor terminals, or motor 

life and pump performance will be lowered.

1.4.

 Always use horsepower-rated switches, contactor 

and starters.

1.5.

 Motor Protection

1.5.1.

 Single-phase: Thermal protection for 

single-phase units is sometimes built in 

(check nameplate). If no built-in protection 

is provided, use a contactor with a proper 

overload. Fusing is permissible.

1.5.2.

 Three-phase: Provide three-leg protection 

with properly sized magnetic starter and 

thermal overloads.

1.6.

 Maximum Operating Limits:

 

Liquid Temperature:  212ºF (100ºC)

 

Pressure: 

125 PSI

 

Starts Per Hour:  

20, evenly distributed

 

Max ambient temperature: 122ºF (50ºC)

 

Consult technical service before operating with  

 

liquid other than water or any other situation  

 

outside operating limits.

1.7.

 Regular inspection and maintenance will increase 

service life. Base schedule on operating time. 

Refer to Section 8.

2. INSTALLATION:

2.1.

 General

2.1.1.

 Locate pump as near liquid source as pos-

sible (below level of liquid for automatic 

operation).

2.1.2. 

Protect from freezing or flooding.

DANGER

WARNING

CAUTION

WARNING

Hazardous fluids can 

cause fire, burns 

or death.

CAUTION

Original Instructions

Summary of Contents for NPE

Page 1: ...Model NPE NPE F INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM013R11...

Page 2: ...Operation 5 Maintenance 5 Disassembly 5 Reassembly 6 Troubleshooting Chart 6 NPE Standard Repair Parts List 7 Mechanical Seal Application Chart 7 Limited Warranty 8 Declaration of Conformity 24 Pump M...

Page 3: ...are fully enclosed non trimable to intermediate diameters Casings are fitted with a diffuser for efficiency and for negligible radial shaft loading Close coupled units have NEMA 48J or 56J motors wit...

Page 4: ...ed solid Allow grout to harden 48 hours before fully tight ening foundation bolts 2 3 5 Tighten pump and motor hold down bolts before connecting the piping to pump 3 SUCTION PIPING 3 1 Low static suct...

Page 5: ...1 Before starting pump must be primed free of air and suction pipe full of liquid and discharge valve partially open Pumped liquid provides lubrication If pump is run dry rotating parts will seize an...

Page 6: ...age may result Replacement of complete seal assembly whenever seal has been removed is good standard practice It is permissible to use a light lubricant such as glycerin to facilitate assembly Do not...

Page 7: ...cknut AISI 316 S S 347 Guidevane AISI 316L S S Viton standard 349 Seal Ring guidevane EPR BUNA 370 Socket head screw casing AISI 410 S S 371 Bolts motor Steel plated 383 Mechanical seal 408 Drain and...

Page 8: ...lacement directions shall terminate Seller s obligations under this Warranty and render the Warranty void Any parts repaired or replaced under the Warranty are warranted only for the balance of the wa...

Page 9: ...Modelo NPE NPE F INSTRUCCIONES DE INSTALACI N FUNCIONAMIENTO Y MANTENIMIENTO MANUAL DE INSTRUCCI N IM013R11...

Page 10: ...aje 13 Reensamble 14 Cuadro de Identificaci n de Problemas 14 Lista de repuestos est ndar NPE 15 Tabla de Aplicaci n del Sello Mec nico 15 Garant a Limitada 16 Declaraci n de Conformidad 24 N mero de...

Page 11: ...n totalmente cerrados y no se pueden recortar a di matros intermedios Las carcasas est n equipadas con un difusor para eficiencia y que las cargas radiales sean negligibles en el eje Las unidades comp...

Page 12: ...enrellenas Dejequelalechadafrag epor48horasantesde apretartotalmentelospernosdelacimentaci n 2 3 5 Apriete los pernos de sujeci n de la bomba y del motor antes de conectar la tuber a a la bomba 3 TUBE...

Page 13: ...nar la bomba en seco las partes que giran se agarrotar n y se da ar el sello mec nico No haga funcionar con caudal muy bajo o cerca de cero La energ a impartida al l quido se convierte en calor y el l...

Page 14: ...un lubricante ligero tal como glicerina para facilitar el montaje No contamine las caras del sello mec nico con lubricante 10 5 2 Inspeccione el anillo en O 513 de la car casa y c mbielo si est da ado...

Page 15: ...casa AISI 316 S S Viton est ndar 412B Anillo en O tap n de drenaje EPR BUNA Viton est ndar 513 Anillo en O carcasa EPR BUNA NOTA COMPONENTES OPCIONALES DEL SELLO A RAS NOTA Las unidades de acoplamient...

Page 16: ...i n o reemplazo del Vendedor rescindir las obligaciones del Vendedor en virtud de esta Garant a y anular esta Garant a Toda pieza reparada o reemplazada en virtud de la Garant a es garantizada solo po...

Page 17: ...Mod lesNPEetNPE F DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN MANUEL D UTILISATION IM013R11...

Page 18: ...Utilisation 21 Entretien 21 D montage 21 Remontage 22 Diagnostic des Anomalies 22 Liste de Pi ces 23 Table des Garnitures Joints M caniques 23 Garantie Limit e 23 D claration de Conformit 24 Informat...

Page 19: ...e un diam tre moindre par usinage Le corps de pompe est muni d un diffuseur pour en am liorer le rendement et diminuer la charge radiale de l arbre Les NPE sont mont es sur des moteurs NEMA 48J ou 56J...

Page 20: ...pieds h 101112131415 16 v v vitesseenpiedsparseconde galUS minx0 321 sectiondepassage galUS minx0 4085 d2 Figure 1 Figure 2 Figure 3 Figure 4 2 3 4 Serrerlesboulonsd ancrage lamainetconstruire uncoffr...

Page 21: ...et la garniture m ca nique se d t riorerait Ne pas faire marcher la pompe quand le d bit est nul ou presque car le liquide absorberait la chaleur produite par frottement et pourrait se changer rapidem...

Page 22: ...garniture dont on ne doit pas con taminer la surface avec le lubrifiant 10 5 2 Inspecter le joint torique 513 du corps de pompe et le remplacer s il est endommag On peut employer du p trolatum vaseli...

Page 23: ...ationduproduit la Garantie Sauf mentioncontrairedansleslois levendeur sonchoixetsansfraispourl acheteur r pareraouremplaceratoutproduitd fectueuxenvertudelagarantiepourautantque l acheteurdonneunavis...

Page 24: ...dise ado para ser incor porado a la maquinaria cubierta por esta directiva pero no debe ponerse en funcionamiento hasta que se declare que la maquinaria en la que ser incorporado cumple con las dispos...

Reviews: