pHix® Compact V3. NG (next generation)
EN 4.10 Version 2103
Mounting /Connection examples
21
Note!
pHix® Compact is a passive transmitter. Considerations should be taken
regarding the voltage drop over the signal cable.
The supply voltage on the site must not drop below 10 V DC at maximum
current (20 mA.)
In order not to compromise operational reliability, the cables should be
interconnected by means of a watertight connection box (item no. 200590).
MJK connection box (item no. 200590).
Connection examples
Local display