– Original Instructions
40
versions only)
E41
Pressure sensor
error 1
No pressure sensor 1 detected
Check the condition of the sensor connection
cables
E42
Pressure sensor
error 2
No pressure sensor 2 detected
Check the condition of the sensor connection
cables
E43
Pressure sensor
error
Missing pressure sensor (not
present in ACT mode)
Check the condition of the sensor connection
cables
E44
Input signal error
No current reference signal
Check the condition of the current signal
connection cables (terminals 9-10 for the single-
phase version, terminals 17-18 for the three-
phase version)
See also Par. 6.3.2 and Par. 6.4.3.