12.
Mechanical seal + O-
ring configuration
[4] = SiC/Carbon/EPDM
[2] = SiC/Carbon/FKM
[Z] = SiC/SiC/EPDM
[W] = SiC/SiC/FKM
[L..] = Tungsten carbide/Metal impregnated carbon/EPDM
[U..] = Tungsten carbide/Metal impregnated carbon/FKM
3.3 Names of the main components of the motor and the inverter
The unit can be fitted with the features the application requires.
Figure 6: Main components - Single-phase and three-phase models
Table 1: Description of components
Position
number
Description
Tightening torque ±15%
[Nm]
[in•lbs]
1
Screw
1.4
12.4
2
Terminal Box Cover
-
-
3
Optional module with strip
-
-
4
M12 I/O cable gland
2.0
17.7
5
M20 cable gland for power supply cables
2.7
23.9
6
M16 I/O cable gland
2.8
24.8
7
Drive (single-phase model)
-
-
8
Motor
-
-
5
2
3
6
4
5
9
1
7
3
9
1
6
4
10
2
1~
3~
ESM_T
00
22
_A_sc
8
ESM_M0
00
5_B_sc
11