en – Original instructions
8
e-IXPSA – Additional Installation, Operation and Maintenance Manual
Temperature
class
Maximum
surface
temperature,
°C (°F)
Temperature
of the
pumped
liquid, °C (°F)
Ambient
temperature, °C (°F)
Notes
T5
100 (212)
85 (185)
-20...+40 (-4…+104) Contact Xylem or its Authorised Distributor
Allowed for these models:
•
≤ 1800 min
-1
40-25-160, 40-25-200, 40-25-250
50-32-160, 50-32-200, 50-32-250
65-50-160, 65-40-200, 65-40-250, 65-40-315
80-65-125, 80-65-160, 80-50-200, 80-50-250, 80-50-315
100-80-125, 100-80-160, 100-65-200, 100-65-250, 100-65-315
125-80-160, 125-80-200, 125-80-250, 125-80-315, 125-80-400, 125-100-160,
125-100-200, 125-100-250, 125-100-315, 125-100-400
150-125-200, 150-125-250, 150-125-315, 150-125-400
200-150-200, 200-150-250, 200-150-315, 200-150-400
250-200-250, 250-200-315
300-250-315
•
≤ 1500 min
-1
—
•
≤ 1000 min
-1
—
T4
135 (275)
120 (248)
-20...+40 (-4…+104)
T3
200 (392)
140 (284)
-20...+40 (-4…+122)
The maximum operating temperature of the pump is shown:
•
In the data sheet or the order confirmation, or both
•
In the name plate on the pump.
1.4.2
Operation of the pump
Filling
During pump operation, fill with the pumped liquid:
•
The suction system
•
The pressure pipe
•
The pump itself.
Also carefully fill:
•
All the sealing chambers
•
The auxiliary systems of the shaft seal
•
Heating system
•
Cooling system
Ensure appropriate monitoring measures, in case the user is unable to guarantee this.
Operation
1.
Start up the pump with the suction side fully open and and the discharge side valve fully
open: start-up with closed non-return valve is however also possible.
2.
Immediately after the start-up, adjust the discharge side valve to the operating point (Section
3.
Before the pump start-up, activate the barrier, flush and cooling systems.
Note: only when the pump is stopped, is shutdown possible, depending on the nature of the
operation.