background image

2

Remote Control Searchlight Model 60080-Series

FEATURES

•  High Output Halogen Sealed Beam Lamp
•  Sleek Design
•  Rugged Construction
•  Full 360° Rotation
•  Weather Resistant Remote Control
•  Corrosion Resistant Lexan® Housing
•  Supplied with 15 ft. (4.5m) Cable with Easy Plug-in Connec-

tions

APPLICATION

Ideal for mid-size boats to locate buoys, moorings, channel 
markers, etc. Ideal for larger motorhomes and bus conversions 
to pinpoint road signs, campsites, or use as a backup light.

SPECIFICATIONS

Voltage:

  

 

 

12 Vdc, 24 Vdc

Amp Draw:

  

 

 

4 (12V), 2 (24V)

Elevation Angle (degrees): 

 

Up 30°, Down: 30°

Housing Material: 

   Lexan

Candle Power: 

 

  175,000

Lux Valve:

  

 

 

15@ 382ft. (100m)

W A R N I N G

Burn Hazard.

 Do not touch lense when light is on.

Do not operate with storage cover over light.

® LEXAN is a registered trademark of General Electric Company.

Model Number

Voltage

Amps

Watts

Bulb Type

Weights lb (kg)

60080-0012

12 Vdc

4

50

SPOT

9 (4.1)

60080-0024

24 Vdc

2

50

SPOT

9 (4.1)

INSTALLATION INSTRUCTIONS

LIGHT MOUNTING

Select a location for the light which will allow a clear beam 
projection forward and as far aft as possible. Searchlight base 
should be mounted on a level, flat surface. A mounting block 
between the searchlight base and mounting surface can be 
used. The block should be contoured to fit the deck so the 
searchlight base is level.
See mounting template attached for plug and cable required 
clearance.

1. 

Mount light with foot of base towards the direction of most 
intended use (front of circular base is marked “front”) with 
gasket under light base.

2. 

Feed wire through hole and secure light in place.
NOTE: Cable connectors are provided for easy wiring 
connections.
Mounting hardware is provided;
4 – 1/4-20 x 2" (6.5 mm x 51 mm) bolts
4 – lockwashers
4 – flatwashers

OPTIONAL
SECONDARY CONTROL MOUNTING

If an additional control station is desired, use control kit 43670-
0004. Mount secondary control in same manner as main con-
trol. Mount station selector panel near the main control (fly-
bridge or lower).

1. 

Cut a 2" x 1-3/8" (51 mm x 35 mm) opening for station 
selector panel within a 1 foot radius of the control.

2. 

Route secondary control cable from station selector panel 
to secondary control location (cable acquired separately—
see cable listing).

3. 

Insert station selector panel thru mounting hole and attach 
connectors to mating connectors from control and search-
light. The connector marked “flybridge” to go to flybridge 
control and the connector marked “lower” to lower control.
The connector to the nearest control can be plugged directly 
into the control. See diagram.

4. 

Use bedding compound or sealant to waterproof station 
selector panel mounting.

5. 

Secure panel with self-tapping screws provided.

CONTROL MOUNTING

Choose a location for the main control near the helm which will 
allow convenient operation. Control may be mounted on verti-
cal, horizontal, or inclined panel.

1. 

Route power leads (supplied by customer) from the volt-
age source to control.
NOTE: Wiring must be 16 gauge with a maximum run of
15 ft. (4.5m)

2. 

Crimp terminals (supplied) onto the power leads,

NOTE: Larger terminal is crimped to positive lead, smaller 
terminal is crimped to negative lead.

3. 

Insert wiring cable through back of hole and plug into control.

4. 

Use bedding compound or sealant to water-proof control.

5. 

Secure control with self-tapping screws provided.

Summary of Contents for JABSCO 60080 Series

Page 1: ...Reflector de control remoto MANUAL DE INSTRUCCIONES Suchscheinwerfer mit Fernbedienung BEDIENUNGSANLEITUNG Zoeklicht met afstandsbediening GEBRUIKSAANWIJZING Projecteur t l command MANUEL D INSTRUCTI...

Page 2: ...ecure light in place NOTE Cable connectors are provided for easy wiring connections Mounting hardware is provided 4 1 4 20 x 2 6 5 mm x 51 mm bolts 4 lockwashers 4 flatwashers OPTIONAL SECONDARY CONTR...

Page 3: ...FT 3m Cable Assembly 43990 0014 15 FT 4 5m Cable Assembly 43990 0015 25 FT 7 6m Cable Assembly 43990 0016 35 FT 11m Cable Assembly NOTE A 15ft 4 5m wiring cable is provided with each light Additional...

Page 4: ...SECONDARY CONTROL CABLE MUST BE ACQUIRED SEPARATELY SEE CABLE LISTING 12 VOLT POWER INPUT LEADS SUPPLIED BY CUSTOMER 16 GA STATION SELECTOR PANEL 12 VOLT POWER INPUT LEADS SUPPLIED BY CUSTOMER 16 GA...

Page 5: ...ABLE FOR ANY OTHER FORM OF DAMAGES WHETHER DIRECT INDIRECT LIQUIDATED INCIDENTAL CONSEQUENTIAL PUNITIVE EXEMPLARY OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFIT LOSS OF ANTICIPATED SAV...

Page 6: ...a commande REMARQUE Le c blage doit tre de calibre 16 avec une longueur maximale de 15 pi 4 5 m 2 Sertissez les cosses fournies sur les cordons d alimenta tion REMARQUE La plus grande borne est sertie...

Page 7: ...2 VOLTS FOURNIS PAR LE CLIENT 16 GA PANNEAU DE S LECTION DE STATION CONTR LER COMMANDE PRINCIPALE D PANNAGE Toutes les lumi res sont soigneusement inspect es avant l exp dition et sont garanties pour...

Page 8: ...v nicht wenn das Licht eingeschaltet ist Nicht mit Aufbewahrungsabdeckung ber dem Licht betreiben LEXAN ist ein eingetragenes Warenzeichen der General Electric Company Modellnummer Stromspannung Strom...

Page 9: ...EN LISTE DER EINZELTEILE Referenzbild auf Seite 3 LISTE DER ZUBEH RKABEL Modell Kit 60080 0012 12V 43670 0004 60080 0024 24V 43670 0004 Modell Nr Lampe 60080 0012 12V 18753 0455 60080 0024 24V 18753 0...

Page 10: ...CHTSMITTEL DES K UFERS UND DIE GESAMTHAFTUNG DES VERK UFERS BEI VERLETZUNG EINER DER VORSTEHENDEN GEW HRLEISTUNGEN AUF DIE REPARATUR ODER DEN ERSATZ DES PRODUKTS BESCHR NKT UND IST IN ALLEN F LLEN AUF...

Page 11: ...a massima di 15 piedi 4 5 m 2 Terminali a crimpare in dotazione sui cavi di alimentazione NOTA il terminale pi grande crimpato sul cavo positivo il terminale pi piccolo crimpato sul cavo negativo 3 In...

Page 12: ...e 60088 1000 7 Braccio di trasmissione ingranaggio 18753 0457 8 Kit viti 18753 0470 Schema elettrico Controllo unico Pannello di selezione della stazione Dimensioni di ingombro Telecomando Dimensioni...

Page 13: ...ONE DETTAGLIATA VISITATECI SU www xylem com it it support CHIAMATE IL NUMERO ELENCATO DELLA NOSTRA SEDE O SCRIVETE UNA LETTERAALVOSTRO UFFICIO REGIONALE Zoeklicht met afstandsbediening NL KENMERKEN Hi...

Page 14: ...bels OPMERKING Grotere aansluiting is gekrompen tot positi eve kabel kleinere aansluiting is gekrompen tot negatieve kabel 3 Steek de bedradingskabel door de achterkant van het gat en steek de stekker...

Page 15: ...lamp werkt niet A Controleer de zekeringen aan de voorkant van de bediening B Controleer de lamp GARANTIE XYLEM BEPERKTE GARANTIE GARANDEERT DIT PRODUCT VRIJ VAN DEFECTEN EN VAKMANSCHAP VOOR EEN PERIO...

Page 16: ...uset p plats OBS Kabelanslutningar medf ljer f r enkla ledningsanslut ningar Monteringsh rdvara medf ljer 4 1 4 20 x 2 6 5 mm x 51 mm bultar 4 l sbrickor 4 plattbrickor FRIVILLIG SEKUND R KONTROLLMONT...

Page 17: ...ssatser kr ver ex tra kablar se kopplingsschema Best ll kabell ngd som kr vs fr n tabellen nedan OBS F st kabeln med nylonkl mmor eller dragkedjor Skydda installationen vid stresspunkter och l mna til...

Page 18: ...ETER ANSVARIG F R N GON ANNAN FORM AV SKADOR VARKEN DIREKTA INDIREKTA LIKVIDERADE OAVSIKTLIGA F LJDSKADOR STRAFSKADOR EXEMPLARISKA ELLER S RSKILDA SKADOR INKLUSIVE MEN INTE BEGR NSADE TILL F RLUSTAV F...

Page 19: ...ntal o inclinado 1 Dirija los cables de alimentaci n suministrados por el cliente desde la fuente de voltaje hasta el control NOTA El cableado debe ser de calibre 16 con un tramo m ximo de 15 pies 4 5...

Page 20: ...a de cableado Control nico Panel de selecci n de estaciones Dimensiones de espacio libre Control remoto Dimensiones de montaje Diagrama de cableado Control remoto secundario opcional CABLES DE ENTRADA...

Page 21: ...YEN LUGAR DETODAS LAS DEM S GARANT AS GARANT AS CONDICIONES O T RMINOS DE CUALQUIER NATURALEZA EXPL CITOS O IMPL CITOS RELACIONADOS CON LOS BIENES SUMINISTRADOS A CONTINUACI N INCLUYENDO SIN LIMITACI...

Page 22: ...C BEFESTIGUNGSBOHRUNG F R 1 4 6 5 mm SCHRAUBE GLEICHM SSIG ABSTAND AUF 5 3 4 146 mm DURCHMESSER B C FORO DI MONTAGGIO PER BULLONE DA 1 4 6 5mm DISTANZA UGUALE SU 5 3 4 146mm DIA B C BEVESTIGINGSGAAT V...

Page 23: ......

Page 24: ...nnovation Park London Road Harlow Essex CM17 9LX Xylem Inc AUSTRALIA 2 2 Capicure Drive Eastern Creek NSW 2766 Xylem Inc CHINA 30 F Tower A 100 Zunyi Road Shanghai 200051 www xylem com jabsco 2022 Xyl...