Lifting equipment
Lifting equipment is always required when handling the unit. It must fulfill the following
requirements:
• The minimum height (contact Xylem for information) between the lifting hook and the
floor must be sufficient to lift the unit.
• The lifting equipment must be able to hoist the unit straight up and down, preferably
without the need for resetting the lifting hook.
• The lifting equipment must be securely anchored and in good condition.
• The lifting equipment must support weight of the entire assembly and must only be
used by authorized personnel.
• Two sets of lifting equipment must be used to lift the unit for repair work.
• The lifting equipment must be dimensioned to lift the unit with any remaining pumped
media in it.
• The lifting equipment must not be oversized.
NOTICE:
Oversized lifting equipment could cause damage if the unit should stick when being
lifted.
Temperature ranges for transportation, handling and storage
Handling at freezing temperature
At temperatures below freezing, the product and all installation equipment, including the
lifting gear, must be handled with extreme care.
Make sure that the product is warmed up to a temperature above the freezing point before
starting up. Avoid rotating the impeller/propeller by hand at temperatures below the
freezing point. The recommended method to warm the unit up is to submerge it in the
liquid which will be pumped or mixed.
NOTICE:
Never use a naked flame to thaw the unit.
Unit in as-delivered condition
If the unit is still in the condition in which it left the factory - all packing materials are
undisturbed - then the acceptable temperature range during transportation, handling and
storage is: –50°C (–58ºF) to +60°C (+140ºF).
If the unit has been exposed to freezing temperatures, then allow it to reach the ambient
temperature of the sump before operating.
Lifting the unit out of liquid
The unit is normally protected from freezing while operating or immersed in liquid, but the
impeller/propeller and the shaft seal may freeze if the unit is lifted out of the liquid into a
surrounding temperature below freezing.
Units equipped with an internal cooling system are filled with a mixture of water and 30%
glycol. This mixture remains a flowing liquid at temperatures down to –13°C (9°F). Below –
13°C (9°F), the viscosity increases such that the glycol mixture will lose its flow properties.
However, the glycol-water mixture will not solidify completely and thus cannot harm the
product.
Follow these guidelines to avoid freezing damage:
Transportation and Storage
8
Flygt 5520 Installation, Operation, and Maintenance Manual