• Do not open any vent or drain valve or remove any plugs while the system is
pressurized. Make sure that the pump is isolated from the system and that pressure is
relieved before you disassemble the pump, remove plugs, or disconnect piping.
• Always bear in mind the risk of drowning, electrical accidents, and burn injuries.
Clean chemicals from the eyes
1. Hold your eyelids apart forcibly with your fingers.
2. Rinse the eyes for at least 15 minutes.
Use an eyewash or running water.
3. Seek medical attention.
Clean chemicals from the body
1. Remove contaminated clothing.
2. Wash the skin with soap and water for at least one minute.
3. Seek medical attention, if required.
Safety regulations for Ex-approved products in potentially explosive atmospheres
General guidelines
ATEX compliance is only fulfilled when the pump is operated within its intended use, for
example within its intended hydraulic range. The conditions of the service must not be
changed without approval of an authorized Xylem representative. When installing or
maintaining ATEX-compliant pumps, follow these guidelines:
• Always install ATEX-approved equipment in compliance with the directive and
applicable standards (IEC/EN 60079–14).
• Always install FM-approved products according to ANSI/NFPA 70-2005.
WARNING:
Installation, Operation, and Maintenance manuals clearly identify accepted methods for
disassembling units. These methods must be adhered to. Trapped liquid can rapidly
expand and result in a violent explosion and injury. Never apply heat to impellers,
propellers, or their retaining devices to aid in their removal.
If there are any questions regarding these requirements, the intended use, or if the
equipment requires modification, contact an Xylem representative before you proceed.
Personnel requirements
Xylem disclaims all responsibility for work done by untrained and unauthorized personnel.
These are the personnel requirements for Ex-approved products in potentially explosive
atmospheres:
• All work on the product must be carried out by certified electricians and Xylem-
authorized mechanics. Special rules apply to installations in explosive atmospheres.
• All users must know about the risks of electric current and the chemical and physical
characteristics of the gas and/or vapor present in hazardous areas.
• The maintenance operation for Ex-approved products must be made in conformity to
the international or national standards (IEC/EN 60079-17).
Product and product handling requirements
These are the product and product handling requirements for Ex-approved products in
potentially explosive atmospheres:
• Only use the product in accordance with the approved motor data stated on the
nameplates.
• The Ex-approved product must never run dry during normal operation. Dry running
during service and inspection is only permitted outside the classified area.
Introduction and Safety
6
Flygt 3201 Installation, Operation, and Maintenance Manual
Summary of Contents for Flygt 3201
Page 1: ...Flygt 3201 Installation Operation and Maintenance Manual...
Page 2: ......
Page 47: ......