The data plate
The data plate is a metal label located on the main body of the pump. The data plate lists
key product specifications. Explosion-proof products also have an approval plate. Both are
described below.
2
13
12
14
22
21
20
17 18
19
16
15
9
10
11
8
7
6
5
4
3
1
23
24
1.
Curve code/Propeller code
2.
Serial number, see
Product denomination
(page 15)
3.
Product number
4.
Country of origin
5.
Additional information
6.
Phase; type of current; frequency
7.
Rated voltage
8.
Thermal protection
9.
Thermal class
10. Rated shaft power
11. International standard
12. Degree of protection
13. Rated current
14. Rated speed
15. Maximum submergence
16. Direction of rotation: L=left, R=right
17. Duty class
18. Duty factor
19. Product weight
20. Locked rotor code letter
21. Power factor
22. Maximum ambient temperature
23. Read installation manual
24. Notified body/only for EN-approved Ex-products
Figure 1: The data plate
Approvals
This section describes the EN and FM approvals that explosion-proof products have. For
more information, please contact your Xylem representative. In addition to the data plate,
explosion-proof products also have either an EN or a FM approval plate.
EN
• European Norm
• ATEX Directive
• EN 50014, EN 50018, EN 1127-1
•
II 2 G EEx d IIB T4
Product Description
14
Flygt 3201 Installation, Operation, and Maintenance Manual
Summary of Contents for Flygt 3201