View of terminal board and sensor connections
775 17 00
2071
2075
3060
3080
MAX 250v
MAX 6A, cos =0,6
MAX 10A, cos =1
SENSORS
WH
WH
T1
T2
THERMAL
DETECTORS
IN STATOR
BN=Brown
BK=Black
WH=White
OG=Orange
GN=Green
GNYE=Green-Yellow
RD=Red
GY=Grey
BU=Blue
YE=Yellow
GC= Ground check
A = Cable dimension in
cable specification
=Terminal board
=Screen
=Ground
=Functional ground
=Jumper
=Crimp connection
=Crimp isolation
SYMBOLS AND DENOMINATIONS
Connection plate
W1
V1
U1
W2
V2
U2
2071
MAIN TERMINAL BOARD
SENSOR TERMINALS
Y (STAR)
JUMPERS
D (DELTA)
JUMPERS
T1
T2
3060
T1
T2
T1
T2
MAIN TERMINAL BOARD
Y (STAR)
JUMPERS
D (DELTA)
JUMPERS
W1
V1
U1
W2
V2
U2
SENSOR TERMINALS
2075
3080
B
U
W
V
Y
X
Z
B
W1 (W)
V1 (V)
U1 (U)
W2 (Z)
V2 (Y)
U2 (X)
T1 (B)
T2 (B)
W1 (3)
V1 (2)
U1 (1)
T1 (4)
T2 (5)
MAIN TERMINAL BOARD STD.
MAIN TERMINAL BOARD Ex
Y (STAR)
JUMPERS
D (DELTA)
JUMPERS