T, °C R, ohms
T, °C R, ohms
T, °C R, ohms
T, °C R, ohms
T, °C R, ohms
31
111.94
64
124.77
97
137.36
130
149.82
32
112.45
65
125.16
98
137.74
131
150.20
8.3 Cable bending radius, weight and diameter
Control cables
Table 22: SUBCAB
™
control cables
This table shows the minimum bending radius, weight, and outer diameter for SUBCAB
control cables.
Cable
Minimum bending radius
in mm
Weight in kg/m
Outer diameter,
minimum-maximum in
mm
12x1.5 mm
2
190
0.53
Ø 18.2–21.2
24x1.5 mm
2
250
0.90
Ø 24.9–28.9
S12x1.5 mm
2
300
0.78
Ø 29.9–31.0
S24x1.5 mm
2
350
1.59
Ø 33.0–37.0
Power cables with power cores and control element
Table 23: Screened SUBCAB
Cable
Minimum bending
radius in mm
Weight in kg/m
Outer diameter,
minimum-maximum in
mm
S3x16 + 3x16/3 + S(4x0.5)
240
1.1
Ø 24–26
S3x25 + 3x16/3 + S(4x0.5)
290
1.4
Ø 29–31
S3x35 + 3x16/3 + S(4x0.5)
320
2.0
Ø 32–34
S3x50 + 3x25/3 + S(4x0.5)
380
3.0
Ø 38–40
S3x70 + 3x35/3 +2 S(2x0.5)
420
3.5
Ø 42–44
S3x95 + 3x50/3 + 2S(2x0.5)
440
4.6
Ø 44–47
3x70/3 + 2S(2x0.5)
500
5.5
Ø 50–52
S6x95 + 95 + S(4x0.5)
570
7.6
Ø 57–60
Table 24: SUBCAB
Cable
Minimum bending
radius in mm
Weight in kg/m
Outer diameter,
minimum-maximum in
mm
4 G 16 + S(2x0.5)
260
1.13
Ø 26–28
4 G 25 + S(2x0.5)
320
1.7
Ø 32–34
4 G 35 + S(2x0.5)
350
2.24
Ø 35–37
3x50 + 2G35/2 + S(2x0.5)
350
2.6
Ø 35–37
3x70 + 2G35/2 + S(2x0.5)
380
3.3
Ø 38–41
3x95 + 2G50/2 + S(2x0.5)
470
4.5
Ø 47–50
3x120 + 2G70/2 + S(2x0.5) 540
5.7
Ø 54–56