INSTALLATION

If the column of water between the 
pump and the highest tap exceeds 15m 
(static discharge head of 15m), the unit 
cannot be installed directly on to the 
pump. The unit has to be raised until the 
column of water between the unit and 
the highest tap does not exceed 15m. I.E. 
if the column of water is 20m above the 
pump, the unit must be placed 5m higher 
than the pump, or have to use a 2.2 Bar 
restarting/cut-in pressure device.

The unit is equipped with a check  
valve to assist preventing the  
pipeline from losing pressure.

PUMP PRESSURE

The 

PC PLUS

 is pre-set by the 

manufacturer to have a restarting/cut in 
pressure of either 1.5 to 

2.

2

 Bar.

To use the 

PC PLUS

 the pressure 

produced by the pump must be  
at least  3 Bar.

Prior to operation, check unit and  
pump are compatible.

Before starting the unit, check suction  
and ensure that the pump is primed. 

No taps or outlets can be installed 
between the pump and the unit.

5

It is advisable to connect the units outlet to the
system by means of a flexible hose.

Safety valve prevents water emission
in case of diaphragm breakage.

The unit is designed to be
installed directly on to the
pump, or between the pump
and the first tap.

Wiring diagram for connection
of single phase 220/240V
pumps up to 1.1 kW.

The productis not

weather-proof.

Do not install in direct

WIRING DIAGRAM

 sunlight. 

for MP and up to 1.5 kW for PC.

4

INSTALLATION INSTRUCTIONS

5

If the column of water between the
pump and the highest tap exceeds 15m
(static discharge head of 15m), the unit
cannot be installed directly on to the
pump. The unit has to be raised until the
column of water between the unit and
the highest tap does not exceed 15m.
I.E. if the column of water is 20m above
the pump, the unit must be placed 5m
higher than the pump, or have to use a
2.2 Bar restarting/cut-in pressure device.

The unit is equipped with a check
valve to assist preventing the
pipeline from losing pressure.

No taps or outlets can be
installed between the
pump and the unit.

PUMP PRESSURE
The PC is pre-set by the manufacturer to
have a restarting/cut in pressure of either
1.5 or 2.2 Bar, while the MP restarting/cut
in pressure is from 1.5 to 2.0 Bar.
To use the PC, the pressure produced by
the pump must be normally 0.8 Bar higher
than the pre-set pressure.  To use the MP,
the pressure produced by the pump must
be at least 3.5 Bar.
Prior to operation check unit and pump
are compatible.
Before starting the unit check suction and
ensure that the pump is primed.

for MP and up to 1.5 kW for PC.

BROWN

BLUE

GREEN YELLOW

GREEN YELLOW

BLUE

BROWN 

L1
N

U

V

PE

L1-1X220/240V

M

1

DANGER
RISK OF
ELECTRIC SHOCK

4

INSTALLATION INSTRUCTIONS

If the column of water between the
pump and the highest tap exceeds 15m
(static discharge head of 15m), the unit
cannot be installed directly on to the
pump. The unit has to be raised until the
column of water between the unit and
the highest tap does not exceed 15m.
I.E. if the column of water is 20m above
the pump, the unit must be placed 5m
higher than the pump, or have to use a
2.2 Bar restarting/cut-in pressure device.

It is advisable to connect the units outlet to the
system by means of a flexible hose.

Safety valve prevents water emission
in case of diaphragm breakage.

DO NOT TOUCH

It is imperative to install the unit
with the arrows in the upward
position.

The unit is designed to be
installed directly on to the
pump, or between the pump
and the first tap.

The unit is equipped with a check
valve to assist preventing the
pipeline from losing pressure.

No taps or outlets can be
installed between the
pump and the unit.

PUMP PRESSURE
The PC is pre-set by the manufacturer to
have a restarting/cut in pressure of either
1.5 or 2.2 Bar, while the MP restarting/cut
in pressure is from 1.5 to 2.0 Bar.
To use the PC, the pressure produced by
the pump must be normally 0.8 Bar higher
than the pre-set pressure.  To use the MP,
the pressure produced by the pump must
be at least 3.5 Bar.
Prior to operation check unit and pump
are compatible.
Before starting the unit check suction and
ensure that the pump is primed.

Wiring diagram for connection
of single phase 220/240V
pumps up to 1.1 kW.

The productis not

weather-proof.

Do not install in direct

WIRING DIAGRAM

 sunlight. 

for MP and up to 1.5 kW for PC.

It is advisable to
connect the units
outlet to the system
by means of a
flexible hose.

Safety valve prevents
water emission in case
of diaphragm breakage.

It is imperative to install
the unit with the arrows
in the upward position.

The unit is designed
to be installed directly
on to the pump, or
between the pump and
the first tap.

DO NOT TOUCH

5

It is advisable to connect the units outlet to the
system by means of a flexible hose.

Safety valve prevents water emission
in case of diaphragm breakage.

The unit is designed to be
installed directly on to the
pump, or between the pump
and the first tap.

Wiring diagram for connection
of single phase 220/240V
pumps up to 1.1 kW.

The productis not

weather-proof.

Do not install in direct

WIRING DIAGRAM

 sunlight. 

for MP and up to 1.5 kW for PC.

4

INSTALLATION INSTRUCTIONS

5

If the column of water between the
pump and the highest tap exceeds 15m
(static discharge head of 15m), the unit
cannot be installed directly on to the
pump. The unit has to be raised until the
column of water between the unit and
the highest tap does not exceed 15m.
I.E. if the column of water is 20m above
the pump, the unit must be placed 5m
higher than the pump, or have to use a
2.2 Bar restarting/cut-in pressure device.

The unit is equipped with a check
valve to assist preventing the
pipeline from losing pressure.

No taps or outlets can be
installed between the
pump and the unit.

PUMP PRESSURE
The PC is pre-set by the manufacturer to
have a restarting/cut in pressure of either
1.5 or 2.2 Bar, while the MP restarting/cut
in pressure is from 1.5 to 2.0 Bar.
To use the PC, the pressure produced by
the pump must be normally 0.8 Bar higher
than the pre-set pressure.  To use the MP,
the pressure produced by the pump must
be at least 3.5 Bar.
Prior to operation check unit and pump
are compatible.
Before starting the unit check suction and
ensure that the pump is primed.

for MP and up to 1.5 kW for PC.

BROWN

BLUE

GREEN YELLOW

GREEN YELLOW

BLUE

BROWN 

L1
N

U

V

PE

L1-1X220/240V

M

1

DANGER
RISK OF
ELECTRIC SHOCK

4

INSTALLATION INSTRUCTIONS

If the column of water between the
pump and the highest tap exceeds 15m
(static discharge head of 15m), the unit
cannot be installed directly on to the
pump. The unit has to be raised until the
column of water between the unit and
the highest tap does not exceed 15m.
I.E. if the column of water is 20m above
the pump, the unit must be placed 5m
higher than the pump, or have to use a
2.2 Bar restarting/cut-in pressure device.

It is advisable to connect the units outlet to the
system by means of a flexible hose.

Safety valve prevents water emission
in case of diaphragm breakage.

DO NOT TOUCH

It is imperative to install the unit
with the arrows in the upward
position.

The unit is designed to be
installed directly on to the
pump, or between the pump
and the first tap.

The unit is equipped with a check
valve to assist preventing the
pipeline from losing pressure.

No taps or outlets can be
installed between the
pump and the unit.

PUMP PRESSURE
The PC is pre-set by the manufacturer to
have a restarting/cut in pressure of either
1.5 or 2.2 Bar, while the MP restarting/cut
in pressure is from 1.5 to 2.0 Bar.
To use the PC, the pressure produced by
the pump must be normally 0.8 Bar higher
than the pre-set pressure.  To use the MP,
the pressure produced by the pump must
be at least 3.5 Bar.
Prior to operation check unit and pump
are compatible.
Before starting the unit check suction and
ensure that the pump is primed.

Wiring diagram for connection
of single phase 220/240V
pumps up to 1.1 kW.

The productis not

weather-proof.

Do not install in direct

WIRING DIAGRAM

 sunlight. 

for MP and up to 1.5 kW for PC.

DANGER
RISK OF ELECTRIC SHOCK

This product is not
weatherproof.

Do not install in direct
sunlight.

Wiring Diagram
Wiring Diagram for connection
of single phase 220/240V pumps
up to 1.1 kW for MP PLUS

Summary of Contents for CentriPro PC PLUS

Page 1: ...com www xylem com au New Zealand Phone 0800 33 19 14 Email enquiriesnz xyleminc com www xylem com nz CentriPro PC PLUS Automatic Pump Controller Installation Operation and Maintenance Manual AS4020 C...

Page 2: ...ensional Drawing 10 CentriPro Limited Warranty 12 CONGRATULATIONS You are now a proud owner of a quality CentriPro product For best results please read this Installation Operation and Maintenance IOM...

Page 3: ...ce with local installation standards Open the terminal front box lid and carry out connections as per the diagram on it Pay attention to the working limits Improper use may damage the controller and o...

Page 4: ...from losing pressure No taps or outlets can be installed between the pump and the unit PUMP PRESSURE The PC is pre set by the manufacturer to have a restarting cut in pressure of either 1 5 or 2 2 Ba...

Page 5: ...diaphragm breakage It is imperative to install the unit with the arrows in the upward position The unit is designed to be installed directly on to the pump or between the pump and the rst tap DO NOT T...

Page 6: ...require the services of an electrician The power lead to the wall socket is supplied with the pump 6 111mmmmm 1 Pump 2 Barrel Union 3 O Ring 5 O Ring 4 MP PLUS Press Control ASSEMBLY INSTRUCTIONS 1 S...

Page 7: ...wo nuts for xing the cable must be tightened rmly Three wire cable with OD 7 5mm 10 5mm Inlet Fig 1 7 ELECTRICAL CONNECTION AND STARTING Failure to comply may cause unit and or pump failure WARNING Ne...

Page 8: ...this case it nds water it will reset and repressurise the system but if it will not nd water it will return in failure and will try to rearm again after 24 hours This process can always be bypassed by...

Page 9: ...s t to oo o l lo ow w P Pu um mp p i is s d di is sc ch ha ar rg ge ed d C Cl lo os se ed d T Ta ap p T Th he e c co ol lu um mn n o of f w wa at te er r o ov ve er r t th he e d de ev vi ic ce e i i...

Page 10: ...10 PC PLUS DIMENSIONAL DRAWING TREVITECH...

Page 11: ...11 NOTES...

Page 12: ...eves that a warranty claim exists must contact the authorised CentriPro dealer from whom the equipment was originally purchased and furnish complete details regarding the claim for warranty This warra...

Reviews: