ELECTRICAL CONNECTION AND STARTING

Failure to comply may cause unit and/or pump failure 

WARNING 
Never take the electronic board out of the control box.

The wiring diagram inside the terminal block indicates how 
to make the correct connection. Incorrect connections will 
destroy the electronic circuit.

The cable used for connection must be three-wire with a 
compulsory ground. 

The cable outer diameter should be 7.5mm minimum and 
10.5mm maximum.  One of the leading ends of the cable must 
be lower than the position of the fixing screws while  the cable is 
being connected to the power as shown in Fig.1

The four screws fastening the panel board and the two cable 
stands for fixing cable must be well fastened to avoid water 
entering the control box and damagi ectronic circuit.

This part must be 
lower than the fixing 
nuts.

The 

three

 

screws must be 
fastened.

The two nuts for fixing 
the cable must be 
tightened firmly.

Three-wire cable 
with OD 7.5mm ~ 
10.5mm

Inlet

Fig. 1

Pump

Barrel 

Union

O Ring

5

O Ring

MP PLUS 

Press 

Control

ASSEMBLY INSTRUCTIONS

Secure the pump on a flat even surface.

Screw the barrel union provided into the discharge port of the pump.

3

Place the O Ring into the recess of the barrel union discharge.

4

Screw the MP PLUS Press Control into the discharge of the barrel 
union by holding the MP PLUS steady and rotate the barrel union anti 
clockwise until secured.

5

The MP PLUS is now secured to the pump and ready to operate.

Special Note  

The MP PLUS is factory fitted with plug and play power leads which connect 
directly to the matching leads as fitted to the pump. These leads are a press fit by 
hand and do not require the services of an electrician.

The power lead to the wall socket is supplied with the pump. 