3535KPM(T) TFT Flat-Panel (Samsung #LTM150XS-T01)
1.
Turn off the power source.
2.
Place the unit on work surface with the display face down.
3.
Unlatch and remove the lid.
4.
If a touch screen is installed, disconnect the touch screen cable.
5.
Disconnect the KEYPAD1, LEDKB1, and MS2 connectors.
6.
Remove the four screws holding the front panel to the display adapter plate.
7.
Remove the unit from the front panel and turn so display is facing up.
8.
Disconnect the bulb connectors from the inverter.
9.
Unscrew the four screws that attach the flat-panel display to the standoffs.
10.
Disconnect the data interface cable from the display.
11.
Gently lay the flat-panel display facedown on a protective surface next to the
unit.
12.
Referring to Figure D-3, unscrew the setscrews that secure the bulb assemblies
and slide the bulb assemblies out of the display.
BULB
CONNECTOR
BULB
ASSEMBLY
(Partially
pulled out)
BULB
CONNECTOR
FLAT
PANEL
DISPLAY
BULB ASSEMBLY
SCREWS (2)
(Remove to free bulb
assembly from display)
Figure D-4. Model #LQ150X1DG16
13.
Insert the new bulb assembly, and fasten the screw to secure.
Note
Xycom Automation recommends replacing both bulbs at the same time.
14.
Reverse steps 1 through 10 to reassemble the unit.