RELAY OUTPUT: Relay output can be connected to external sounding device or
warning device.
Two Types (NO/ NC) of Relay Output Setup:
ON: Relay output enabled.
OFF: Relay output disabled.
PERIOD: Duration time of the relay output.
Relay output event includes the following:
1. VIDEO LOSS: Triggered by video loss.
2. MOTION DETECTION: Triggered by motion detection.
3. ALARM: Triggered by external alarm.
7.8.4 ALARM INPUT
A L A R M
I
N P U T
S
E
T U P
7
-
4
A
L
1
1
1
1
1
1
1
C H
L
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
O O O O O O O O O O O O O O O O O
[
D E
F A U
L
T
]
+
:
E A C H
-
:
D
I
S A B
L E
O
:
N O
C
:
N C
Sensor Type
:
NC
→
Normal Close Alarm ( TTL level input )
Setup NC (Normal Close), the alarm will be triggered during NC status.
NO
→
Normal Open Alarm ( TTL level input )
Setup NO (Normal Open), the alarm will be triggered during NO status.
ALL
+ (EACH): Alarm input can be individually setup to NC or NO.
- (DISABLE): Disable all alarm input function.
C: All alarm input is setup to NC.
O: All alarm input is setup to NO.
27