Troubleshooting
TS04-S-IDU: The Indoor fan speed is operating outside of normal range diagnosis and
solution)
Description
: When indoor fan speed keeps too low or too high for a certain time, the LED displays the failure code and
the AC turns off.
Recommended parts to prepare:
• Connection wires
• Fan assembly
• Fan motor
• Indoor main PCB
Troubleshooting and repair:
YES
Power off, then restart the unit after 2 minutes.
Is it within normal parameters?
Replace the fan motor
Does a problem remain?
The unit is operating normally
NO
Shut off the power supply, Rotate
the fan by hand.
YES
Does it turn easily?
Find the cause of the problem and resolve it
NO
Check the wiring of fan motor.
YES
Is it improperly wired?
Ensure proper connections
Measure the voltage for
the fan motor from the PCB.
YES
Replace the indoor main PCB
NO
Summary of Contents for MSAGBU-09HRFN8-QRD1GW
Page 1: ...XTREME 3D INVERTER SERIES SM_AG GA _R32_3D INV_EU_NB_2006 SERVICE MANUAL ...
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions ...
Page 18: ...Outdoor unit wiring diagram 16022000019533 ...
Page 56: ... Outdoor Unit Disassembly 3 2 Dimension 1 Panel Plate AA30 ...
Page 57: ... Outdoor Unit Disassembly 4 2 Panel Plate AB30 ...
Page 58: ... Outdoor Unit Disassembly 5 3 Panel Plate BA30 ...
Page 59: ... Outdoor Unit Disassembly 6 For US models ...
Page 60: ... Outdoor Unit Disassembly 7 4 Panel Plate B30 ...
Page 61: ... Outdoor Unit Disassembly 8 For US models ...
Page 62: ... Outdoor Unit Disassembly 9 5 Panel Plate CA30 ...
Page 63: ... Outdoor Unit Disassembly 10 For US models ...
Page 64: ... Outdoor Unit Disassembly 11 6 Panel Plate D30 ...
Page 65: ... Outdoor Unit Disassembly 12 For US models ...
Page 66: ... Outdoor Unit Disassembly 13 7 Panel Plate X130 ...
Page 67: ... Outdoor Unit Disassembly 14 For US models ...
Page 68: ... Outdoor Unit Disassembly 15 8 Panel Plate X230 ...
Page 69: ... Outdoor Unit Disassembly 16 For US models ...
Page 70: ... Outdoor Unit Disassembly 17 9 Panel Plate X330 ...
Page 71: ... Outdoor Unit Disassembly 18 For US models ...
Page 72: ... Outdoor Unit Disassembly 19 10 Panel Plate X430 ...
Page 73: ... Outdoor Unit Disassembly 20 For US models ...