![Xtreme MSAGBU-09HRFN8-QRD1GW Service Manual Download Page 14](http://html1.mh-extra.com/html/xtreme/msagbu-09hrfn8-qrd1gw/msagbu-09hrfn8-qrd1gw_service-manual_3762096014.webp)
2. Pipe Length and Drop Height
The length and elevation of connection pipe are shown in the table below. if the pipe length exceeds max pipe length,
additional refrigerant should be charged to ensure nominal cooling/heating capacity.
Capacity(Btu/h)
Standard Length
Max Pipe Length
Max Elevation
Additional Refrigerant
9k/12k
5m (16.4ft)
25m (82.0ft)
10m (32.8ft)
12g/m (0.13oz/ft)
If oil flows back into the outdoor unit’s compressor, this might cause liquid compression or deterioration of oil return. Oil
traps in the rising gas pipe can prevent this.
1. Indoor unit is installed higher than outdoor unit
2. Outdoor unit is installed higher than indoor unit
If indoor unit is installed higher than outdoor unit, oil trap should be set every 10m(32.8ft) of vertical distance.
If the outdoor unit is installed higher than the indoor unit, proper oil should return to the compressor along with the
suction of refrigerant to keep lubrication of compressor. If the suction flow velocity drops below 7.62m/s(1500fpm (feet
per minute)), oil won’t return to the compressor. An oil trap should be installed every 6m(20ft) of vertical distance.
Specifications 3
Summary of Contents for MSAGBU-09HRFN8-QRD1GW
Page 1: ...XTREME 3D INVERTER SERIES SM_AG GA _R32_3D INV_EU_NB_2006 SERVICE MANUAL ...
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions ...
Page 18: ...Outdoor unit wiring diagram 16022000019533 ...
Page 56: ... Outdoor Unit Disassembly 3 2 Dimension 1 Panel Plate AA30 ...
Page 57: ... Outdoor Unit Disassembly 4 2 Panel Plate AB30 ...
Page 58: ... Outdoor Unit Disassembly 5 3 Panel Plate BA30 ...
Page 59: ... Outdoor Unit Disassembly 6 For US models ...
Page 60: ... Outdoor Unit Disassembly 7 4 Panel Plate B30 ...
Page 61: ... Outdoor Unit Disassembly 8 For US models ...
Page 62: ... Outdoor Unit Disassembly 9 5 Panel Plate CA30 ...
Page 63: ... Outdoor Unit Disassembly 10 For US models ...
Page 64: ... Outdoor Unit Disassembly 11 6 Panel Plate D30 ...
Page 65: ... Outdoor Unit Disassembly 12 For US models ...
Page 66: ... Outdoor Unit Disassembly 13 7 Panel Plate X130 ...
Page 67: ... Outdoor Unit Disassembly 14 For US models ...
Page 68: ... Outdoor Unit Disassembly 15 8 Panel Plate X230 ...
Page 69: ... Outdoor Unit Disassembly 16 For US models ...
Page 70: ... Outdoor Unit Disassembly 17 9 Panel Plate X330 ...
Page 71: ... Outdoor Unit Disassembly 18 For US models ...
Page 72: ... Outdoor Unit Disassembly 19 10 Panel Plate X430 ...