Back Panel (3000VA), 3U SIZE 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
2.1 “Power On” Indicator   

Power On indicator illuminates when utility power’s condition is normal. 

 

 

2.2 

BACKUP

 indicator 

The indicator illuminates when the power is supplied from the batteries. 
 

2.3 “Battery Fault

 Indicator   

This illuminates indicating weak battery. Recharge the battery for at least four 
hours. If after recharging this is still illuminated, replace the battery by following 
the instructions in the manual.(You can plug out then check battery) 
 

2.4 Power Switch   

Can be used as the master on/off switch of your equipment by leaving your 
equipment connected to UPS and switched on. 
 

2.5 UPS Outlets     

Provide instantaneous back-up power protection to your equipment. Supply 
temporary uninterrupted operation for your equipment during power failure. 
 

2.6 Bypass Power Sag Outlets 

Provides bypass power sag protection to your equipment. Prevent power 

 

8

problems traveling through your system via unprotected peripherals. 

2.7 Circuit Breaker Protection 

Serves as an overload and fault protection. This is a critical component of the 
advanced UPS 
 

2.8 “Phone Jack” Communications Ports   

Telecom transfer ports provide users to extend the applications. 

Caution:

 

To reduce the risk of fire, use only No. 26AWG or larger 

telecommunication line cord. 

 

2.9 communication function 

Provide RS-232 interface and UPSMON software to support NOVELL, UNIX, 
DOS, WINDOWS and other operating systems.   

 

3. Installation

 

 
Inspect the UPS upon receipt. The packaging is recyclable; keep it for reuse or 
dispose of properly. 

3.1 Recharge the battery 

UPS may be used by anyone immediately upon receipt. The battery is fully 
charged before shipping from the factory. However, the user is recommended to 
recharge the battery for at least eight hours before using UPS. Energy loss may 
occur during shipping or long duration storage. To recharge the battery, simply 
plug in the UPS to a wall outlet and let it charge. 

3.2 Connect the loads 

Plug your primary equipment (e.g. computer, monitor and critical data storage 
device, etc.) to the Battery Power-Supplied outlets. Plug your peripheral 
equipment (e.g. printer, scanner, fax, or audio device) to the bypass outlets. Do 
not plug a laser printer into the UPS output outlets, as its power demand is much 
higher than typical peripherals and may cause the circuit breaker to trip. It is 
suggested to connect  similar heavy loads (like laser printer) to the bypass 
outlets. 

3.3 Connect the telephone 

If you wish to protect a fax or a modem, connect the telephone cable from the wall 
outlet to the “IN” jack. Connect the telephone cable (provided) from the “OUT” jack 
to the fax or modem. To protect a10Base-T (UTP) network interface, obtain and 
use a UTP cable to connect the “OUT” jack to your computer. 

3.4 Connect to the utility power 

Plug UPS to a 2-pole, 3-wire grounding receptacle. Make sure the branch is 
protected and does not service equipment requiring heavy electricity (e.g. 
refrigerator, air conditioner, copier, etc.). Avoid using extension cords; if used, 
make sure they are rated for at least 15 Amps (A). 
 

Special Note

:: concerning connection to utility power

  .   S i z e   o f   B r a n c h  

C i r c u i t   O v e r c u r r e n t  P r o t e c t i o n  -   " C A U T I O N  -   To   r e d u c e   t h e  

r i s k   o f   f i r e ,   c o n n e c t   o n l y   t o   a   c i r c u i t   p r o v i d e d   w i t h   3 0  

a m p e r e s   m a x i m u m   b r a n c h   c i r c u i t   o v e r c u r r e n t   p r o t e c t i o n   in  

a c c o r d a n c e   w i t h   t h e   N a t i o n a l   E l e c t r i c   C o d e ,  A N S I / N F PA  7 0 " .

 

3.5 UPS self-test 

UPS will conduct a self-test once switched on it each time. Do not add or take off 

Summary of Contents for XVT 600VA

Page 1: ...U P S Uninterruptible Power System Xtreme Value Rack Tower XVRT Line Interactive Rack Mount Network UPS 600VA 1000VA 1200VA 1500VA 2200VA 3000VA...

Page 2: ...USER S MANUAL...

Page 3: ...and correct installation of the UPS If you should have any problems with the UPS please refer to this manual before calling customer service Please save or recycle the packaging materials The UPS s sh...

Page 4: ...Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and their required precautions Keep unauthorized personnel away from batteries When Replacing Batterie...

Page 5: ...5 2 Presentation Front Panel 600VA 1000VA 1U size Front Panel 1200VA 1500VA 2U size Front Panel 2200VA 3000VA 3U size Back Panel 600VA 1000VA 1U size Back Panel 1200VA 1500VA 2U SIZE...

Page 6: ...6 1500VA 110V NO BYPASS OUTPUT Back Panel 2200VA 3U SIZE...

Page 7: ...ter recharging this is still illuminated replace the battery by following the instructions in the manual You can plug out then check battery 2 4 Power Switch Can be used as the master on off switch of...

Page 8: ...tlets Plug your peripheral equipment e g printer scanner fax or audio device to the bypass outlets Do not plug a laser printer into the UPS output outlets as its power demand is much higher than typic...

Page 9: ...l status of battery make sure the UPS remains plugged in 3 9 Self protection feature UPS is equipped with a self protection feature preventing people users from damaging the unit It is programmed so t...

Page 10: ...ion with bottom plate Part RMB 08 1U RMB 09 2U RMB 10 3U RMB 11 4U 2 PCS Installation with bottom bracket Part RMB 12 1U 4U 2 PCS Installation with rear bracket Part RMB 13 RMB 14 2U 4U 4 PCS Step 1 S...

Page 11: ...ng UPS for the first time or when adding an additional piece of equipment Conduct a simulation test first switch on UPS and wait for the power indicator to light up then simply unplug UPS to simulate...

Page 12: ...oring software is applied via a standard RS 232 interface to perform monitoring functions and then provides an orderly shutdown of a computer in the event of power failure Moreover UPSMON displays all...

Page 13: ...model name with P affix The standard RS 232 cable pin to pin D SUB 9 pin cable can be connected between UPS REMOTE PORT and computer COM port for the UPSMON series software UPSMON software can be free...

Page 14: ...piece of equipment from the UPS outlets UPS doesn t perform to its expected runtime The battery is slightly worn out Call the service personnel to replace the battery Special UPS is designed to preve...

Page 15: ...output cut off immediately or input fuse protection Type Sealed Maintenance free lead acid Typical Recharge Time 8 hours to 90 of full capacity Protection Automatic self test discharge protection Repl...

Page 16: ...of full capacity Protection Automatic self test discharge protection Replace battery indicator Battery Back up Time 3 180 min depending on computer load MAXIMUM Ambient Temperature For Operation 0 35C...

Page 17: ...al Authorization Number RMA G If the UPS is under warranty the repairs will be done at no charge If not there will be a charge for repair 4 Pack the UPS in its original packaging If the original packa...

Page 18: ...tteries Batteries included in this product are warranted for two years Batteries are deemed defective by Xtreme Power s sole discretion Limitations of Warranty This limited warranty does not cover any...

Page 19: ...yees affiliates resellers partners and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim or personal inju...

Page 20: ...w replacement product or repair the returned product The customer must return the defective unit to Xtreme Power within 30 days of issuance of the RMA or will be charged full price for the replacement...

Reviews: