background image

 

3

Table of contents

 

Table of contents................................................................................. 3 

Introduction......................................................................................... 3 

1. Important Safety Instructions ......................................................... 4 

2. Presentation..................................................................................... 5 

3. Installation ...................................................................................... 8 

4. Operation .......................................................................................11 

5. Software and Computer Interface ................................................. 12 

6. Battery Cabinet ............................................................................. 13 

Appendix a Troubleshooting............................................................. 13 

Appendix b Specifications ................................................................ 14

 

Obtaining Service ............................................................................. 15

 

Warranty............................................................................................ 16

 

 

I n t r o d u c t i o n

 

 

Please read and save this manual! 

Thank you for selecting this uninterruptible power system (UPS). It provides you 
with a perfect protection for connected equipment. The manual is a guide to install 
and use the UPS. It includes important safety instructions for operation and 
correct installation of the UPS. If you should have any problems with the UPS, 
please refer to this manual before calling customer service. 
 

Please save or recycle the packaging materials! 

The UPS‘s shipping materials are designed with great care to provide protection 
within delivery. These materials are invaluable if you ever have to return the UPS 
for service. Damage happened during transit is not covered under the warranty. 
 

Intelligent microprocessor control   

The UPS is a microprocessor-controlled unit. This means that it operates with the 
newest technology, high performance and powerful function.   
 
The UPS is an intelligent protector and provides pure, reliable AC power to the 
critical loads - protecting them from utility power blackout, swells, sags and 
interference.  
 

 

4

Furthermore, in order to save the battery energy, the UPSs can automatically turn 
it off under backup mode if none of the connected loads is operating. 
 

Advanced battery management 

The visual and audible indications of the UPS present the battery’s status. The 
self-test function allows the UPS to detect a weak battery before it is put into 
service. The UPS normally performs a self-test at power up condition.   
 
 

1. Important Safety Instructions

 

 

●  

SAVE THESE INSTRUCTIONS

 - 

This Manual Contains Important 

Instructions that should be Followed during Installation and Maintenance of 
the UPS and Batteries.   

●  

Intended for Installation in a Controlled Environment. 

 

●  

Servicing of batteries should be performed or supervised by personnel 
knowledgeable of batteries and their required precautions. Keep 
unauthorized personnel away from batteries. 

 

●  

When Replacing Batteries, replace With the Same Number and Type 

 

●  

CAUTION

  -

 Do Not Dispose of Battery or Batteries in a Fire, The Battery 

May Explode. 

 

●  

CAUTION

  -

 Do Not Open or Mutilate the Battery or Batteries, Released 

Electrolyte  
is Harmful to the Skin and Eyes. It May be Toxic. 
 

●  

CAUTION

 -

 A Battery can present a Risk of Electrical Shock and High Short 

Circuit Current. The Following Precautions Should be Observed When 
Working on Batteries: 

      Remove watches, rings or other metal objects. 
   Use tools with insulated handles. 
      Wear rubber gloves and boots. 
      Do not lay tools or metal parts on top of batteries. 
   Disconnect charging source prior to connecting or disconnecting battery 

 terminals. 

 
 
 
 
 
 

Summary of Contents for XVT 600VA

Page 1: ...U P S Uninterruptible Power System Xtreme Value Rack Tower XVRT Line Interactive Rack Mount Network UPS 600VA 1000VA 1200VA 1500VA 2200VA 3000VA...

Page 2: ...USER S MANUAL...

Page 3: ...and correct installation of the UPS If you should have any problems with the UPS please refer to this manual before calling customer service Please save or recycle the packaging materials The UPS s sh...

Page 4: ...Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and their required precautions Keep unauthorized personnel away from batteries When Replacing Batterie...

Page 5: ...5 2 Presentation Front Panel 600VA 1000VA 1U size Front Panel 1200VA 1500VA 2U size Front Panel 2200VA 3000VA 3U size Back Panel 600VA 1000VA 1U size Back Panel 1200VA 1500VA 2U SIZE...

Page 6: ...6 1500VA 110V NO BYPASS OUTPUT Back Panel 2200VA 3U SIZE...

Page 7: ...ter recharging this is still illuminated replace the battery by following the instructions in the manual You can plug out then check battery 2 4 Power Switch Can be used as the master on off switch of...

Page 8: ...tlets Plug your peripheral equipment e g printer scanner fax or audio device to the bypass outlets Do not plug a laser printer into the UPS output outlets as its power demand is much higher than typic...

Page 9: ...l status of battery make sure the UPS remains plugged in 3 9 Self protection feature UPS is equipped with a self protection feature preventing people users from damaging the unit It is programmed so t...

Page 10: ...ion with bottom plate Part RMB 08 1U RMB 09 2U RMB 10 3U RMB 11 4U 2 PCS Installation with bottom bracket Part RMB 12 1U 4U 2 PCS Installation with rear bracket Part RMB 13 RMB 14 2U 4U 4 PCS Step 1 S...

Page 11: ...ng UPS for the first time or when adding an additional piece of equipment Conduct a simulation test first switch on UPS and wait for the power indicator to light up then simply unplug UPS to simulate...

Page 12: ...oring software is applied via a standard RS 232 interface to perform monitoring functions and then provides an orderly shutdown of a computer in the event of power failure Moreover UPSMON displays all...

Page 13: ...model name with P affix The standard RS 232 cable pin to pin D SUB 9 pin cable can be connected between UPS REMOTE PORT and computer COM port for the UPSMON series software UPSMON software can be free...

Page 14: ...piece of equipment from the UPS outlets UPS doesn t perform to its expected runtime The battery is slightly worn out Call the service personnel to replace the battery Special UPS is designed to preve...

Page 15: ...output cut off immediately or input fuse protection Type Sealed Maintenance free lead acid Typical Recharge Time 8 hours to 90 of full capacity Protection Automatic self test discharge protection Repl...

Page 16: ...of full capacity Protection Automatic self test discharge protection Replace battery indicator Battery Back up Time 3 180 min depending on computer load MAXIMUM Ambient Temperature For Operation 0 35C...

Page 17: ...al Authorization Number RMA G If the UPS is under warranty the repairs will be done at no charge If not there will be a charge for repair 4 Pack the UPS in its original packaging If the original packa...

Page 18: ...tteries Batteries included in this product are warranted for two years Batteries are deemed defective by Xtreme Power s sole discretion Limitations of Warranty This limited warranty does not cover any...

Page 19: ...yees affiliates resellers partners and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim or personal inju...

Page 20: ...w replacement product or repair the returned product The customer must return the defective unit to Xtreme Power within 30 days of issuance of the RMA or will be charged full price for the replacement...

Reviews: