1 5
Voltage Regulation
(AVR)
AVR automatically increase output voltage 15% above input voltage
if –9% to –25% of nominal. AVR decrease output voltage 13% below
input voltage if +9% to +25% of nominal
Transfer Time
2/4 milliseconds, including detection time
Spike Protection
320 Joules, 2ms
EMI/RFI filter
10Db at 0.15MHz,50dB at 30MHz
Overload Protection
UPS automatic shutdown if overload exceeds 110% of nominal at 60
seconds and 130% at 3 seconds
Unit Input
For overload & Short circuit protection
10Base-T Cable Port
Network (UTP, RJ-45) compatible jacks
Protection
and
Filtering
Short Circuit
UPS output cut off immediately or input fuse protection
Type
Sealed, Maintenance-free lead acid
Typical Recharge Time
8 hours (to 90% of full capacity)
Protection
Automatic self-test & discharge protection, Replace battery indicator
Battery
Back-up Time
3– 180 min (depending on computer load)
MODEL
1500VA 2200VA 3000VA
Input Capacity
(On
Battery)
1500VA/900W 2200VA/1320W 3000VA/1800W
(Surge
protection)
500VA for 220~240V
Models only
N/A N/A
Voltage
+/-25% at line input
Frequency
50 or 60 Hz +/-10% (auto sensing)
Voltage (on battery)
Simulated sine wave at 100V/115V/230V +/- 5%
Frequency (on battery)
50 or 60 Hz +/- 0.5%
Output
Voltage Regulation
(AVR)
AVR automatically increase output voltage 15% above input voltage
if –9% to –25% of nominal. AVR decrease output voltage 13% below
input voltage if +9% to +25% of nominal
1 6
Transfer Time
2/4 milliseconds, including detection time
Spike Protection
320 Joules, 2ms
EMI/RFI filter
10Db at 0.15MHz,50dB at 30MHz
Overload Protection
UPS automatic shutdown if overload exceeds 110% of nominal at 60
seconds and 130% at 3 seconds
Unit Input
For overload & Short circuit protection
10Base-T Cable Port
Network (UTP, RJ-45) compatible jacks
Protection
and
Filtering
Short Circuit
UPS output cut off immediately or input fuse protection
Type
Sealed, Maintenance-free lead acid
Typical Recharge Time
8 hours (to 90% of full capacity)
Protection
Automatic self-test & discharge protection, Replace battery indicator
Battery
Back-up Time
3– 180 min (depending on computer load)
MAXIMUM Ambient Temperature
For Operation
0-35C for Ambient operation
All trademarks are property of their respective owners. Specifications
subject to change without notice.
O
B TA I N I N G S E RV I C E
E n g l i s h
I f t h e U P S r e q u i r e s S e r v i c e :
1 . U s e t h e
T R O U B L E S H O O T I N G
s e c t i o n t o e l i m i n a t e o b v i o u s
c a u s e s .
2. Verify there are no circuit breakers tripped
3 . C a l l y o u r d e a l e r f o r a s s i s t a n c e . I f y o u c a n n o t r e a c h y o u r
d e a l e r , o r i f t h e y c a n n o t r e s o l v e t h e p r o b l e m c a l l o r f a x X t r e m e
P o w e r T e c h n i c a l S u p p o r t a t t h e f o l l o wi n g n u m b e r s ; V o i c e
p h o n e _ , F a x l i n e _ o r C o n t a c t X t r e m e P o we r a t 8 0 0 - 5 8 2 - 4 5 2 4 .