background image

Xtreme Power Conversion Corporation

XPD0215SL User’s Manual

Page 15

Power Distribution Unit

Power Outlet Setup Menu (Web Page)

Name:

Define a name for the power outlet.

On/Off:

Set the power outlet to power on or off state.

Reservation:

Reserve the port for special user.

AutoPing and reboot (Power reboot If user equipment’s network is down)

Disable or enable AutoPing power reboot function. If it is enabled, the system schedules auto pings to the com-

munication equipment that is connected to the power outlet. If no response is received in a period of time (user 

defined, see below) from the communication equipment, the system starts the power reboot process for the 

power outlet.

Ping Ip(AutoPing (Ping) destination IP address) :

Enter an IP address of the probed communication equipment. This IP address is associated to the power outlet.

Email notify if autoping failed

Disable or enable sending email notify if autoping failed. Only available if AutoPing and reboot if on.

Reboot Duration In Seconds

Setting the reboot duration if the autping is failed or clicking “Reboot” push switch button icon. The unit is second.

Summary of Contents for XPD0215SL

Page 1: ...XPD0215SL Switched PDU User Installation Manual www xpcc com 2015 Xtreme Power Conversion Corporation All rights reserved Rev 6 18 15 ...

Page 2: ...ter Port Access 8 External Modem Access 8 Telnet Access 8 WebAccess 9 Email Access 10 SNMP Information 11 AutoPing and Power Reboot 12 UsingControlCommand 12 Using Configuration Menu 14 Starting Configuration Menu 14 Viewing and Changing Operation Status 14 Power Outlet Setup Menu 14 Power Outlet Timer Setup Menu 16 User Account Setup Menu 18 System Access Setup Menu 19 Serial Port Setup Menu 20 T...

Page 3: ...Safety Standards Compliance NP Series products are tested and manufactured in accordance with the following test requirements listed EN55022 2006 EN6100 3 2 2006 EN6100 3 36 1995 A1 2001 A2 2005 EN55024 1998 A1 2001 A2 2003 EN60950 1 2006 Warranty Information The warranty period for this product is one 1 year from the date of purchase Please contact Shanghai Qianjin Electronic Equipment Co Ltd at ...

Page 4: ...tings and operate unreserved power outlets and serial console ports User name and password for each port The user name and password are protected in each ports Line commands or menu configuration controls Menu table operation offers user friendly operation methods that are used for changing system configurations viewing run time statuses and issuing controls Line commands provide quick and easy op...

Page 5: ...s you are able to manage the systems or user commu nication equipment power sources when LAN access is impossible Via emails you can send user data to the NP control commands such as rebooting user power source Reply emails are sent after the system intercepts incoming emails so that you are informed with the operation status AutoPing and reboot user equipment Connect your system to a power outlet...

Page 6: ...es 1 4 outlets 16 Series 1 8 outlets 23 Power Circuit A Switched Outlets AC Outlets that can be switched On Off or rebooted in response Important Safety Precautions for Hardware Installation Safety Precautions It is important that you read this section before attempting any of the hardware installation and maintenance procedures in this guide The following instructions are important for your safet...

Page 7: ...rity 1 stop bit and no hardware handshaking Flow Control The default Ethernet setting are IP 192 168 1 100 GateWay 192 168 1 1 NetMask 255 255 255 0 The default Administrator s login name admin and the default password is admin and user s login name user and the default password is user All existing user accounts are erased if the system is recovered to the default settings The default SNMP Commun...

Page 8: ...n a terminal emulation program such as Window s Hyper Terminal on your computer 1 Connect the system s Local Master Port DCE with a straight DB 9 type cable if your work station is equipped with a DTE part 2 Connect the system s Ethernet port to your LAN if you intend to use the network port 3 Turn the system power on 4 At the terminal emulation program type the help for help information 5 The sys...

Page 9: ...and Port Reservations for further information There are 8 Telnet session at most may be active at the same time A Telnet session remains active for 10 minutes if it is in idle state Telnet access methods can be enabled or disabled using the System Access Setup Menu To terminate an active Telnet session use the command exit at the terminal Telnet Session Startup Screen Web Access You need to obtain...

Page 10: ...er name is admin The default password is admin Web Access Login Entry Table Email Access To establish this access method the system s network connection is already established With the email access method you are able to execute the NP system controlling commands The NP system periodically checks incom ing mails from a designated POP mail server The system sends a reply email with command process ...

Page 11: ...odifies the value of a variable You need to know the name of a variable before you can fetch or modify a variable s value A variable s symbolic name is mapped to a numeric name which is referred as OID The MIB Management Information Base is a text file describing the internal objects the SNMP agent can display monitor and or modify Each MIB object is the system variable that has name and an OID as...

Page 12: ...em also pings the gateway IP address as default to make sure a NP system has a network connection that is still active Otherwise AutoPing will be in off mode if a NP system lost network connection To change the default gateway IP address as ping destination use TCP IP Configuration Menu to enter your desired destination address Using Control Command A NP system provides command line options for vi...

Page 13: ...ff ps v Sets all power outlets to v value 1 on 0 off prb n Reboot power outlet n prsv n Reserve power outlet n for current user punrsv n Unreserve power outlet n for current user mac print the mac addr ping 10 10 26 236 ping an ip address acl 0 1 Disable Enable ACL aclset id type mask id 1 6 type 0 Not Care 1 Permit 2 Block mask ip smtp lalalalala send an email getmail fetch mail from pop3 server ...

Page 14: ...on and the system are connected to LAN Viewing and Changing Operation Status System Operation Static Web Page With this web page you are able to View on off status for each power outlet As shown in the table Power outlet 1 is power on illuminated in red and outlet 2 is power off not illuminated in grey Change power outlet on off status by clicking on off switch button icon Reboot a power outlet by...

Page 15: ...ation equipment that is connected to the power outlet If no response is received in a period of time user defined see below from the communication equipment the system starts the power reboot process for the power outlet Ping Ip AutoPing Ping destination IP address Enter an IP address of the probed communication equipment This IP address is associated to the power outlet Email notify if autoping f...

Page 16: ... Power Outlet Status Terminal Screen Power Outlet Timer Setup Menu This is an example of the power outlet in Timer off mode To enable the Timer select Timer Mode on Power Outlet Timer Setup Menu Web Page Timer Mode Select the timer mode Off Standard Customized Timer Start Time Specify starting time for the timer The starting time is the actual calendar date and real time clock Once a timer reaches...

Page 17: ... duration is in seconds The concept of the specification can also be viewed as Duty Cycle The value of this parameter should be 0 Toggle Duration Timer Period ON Off Timer Period Loop Count 1 Loop Count 2 Loop Count 3 Loop Count 4 Timer Start Time Toggle Duration Definitions of Timer Parameters There are a few examples of applications using the Power Outlet Timers 1 Reboot daily Current Calendar d...

Page 18: ...e event at 1 00am 2009 on Feb 12th Timer Period 6 6 seconds Timer Toggle Duration 5 5 seconds Reboot duration is 5 seconds Timer Loop Count 1 Reboot once User Account Setup Menu User account management includes reserving or un reserving each serial console ports and power outlets to a current login user as well as adding new user accounts modifying and deleting user accounts User Account Managemen...

Page 19: ...device An external Modem device is typically equipped with a DCE Data Communication Equipment terminal connector Since the system s Local Master Port and Modem device ports are not complementary you need to use a NULL Modem cable with both male connectors For information about connecter pin assignment please see appendix A Modem Startup String Define an external Modem control command string that i...

Page 20: ...twork Management System using SNMP Please see Section 2 5 for a available MIB objects that the system supports Default to disable SNMP Trap Enabling Enable or disable Trap sending If this option is enabled Traps are sent if there is a power reboot command execu tion on the system Default to disable Note you must enable the above SNMP Agent setting Otherwise enabling Trap setting will not take effe...

Page 21: ...ts Please also note that when Telnet access is used for exchanging data between the system s Ethernet interface port and user communication equipment without enabling flow control you might experience data loss when data exchange rate is high This is because data flow from the system s Ethernet port is subject to the congestion condi tion of LAN traffic Data Bit Supports 7 or 8 bits Stop Bits Supp...

Page 22: ...ng DHCP Enable or disable DHCP The purpose of using DHCP Dynamic Host Configuration Protocol is to assign dynamic IP addresses to a computer or a network device on a network There must be a DHCP server on a network running and the server must permit an assigned computer or network device to be on the LAN If this option is disabled the system will not send DHCP requests to a network ...

Page 23: ...P manually Primary DNS IP Specifies a priamary DNS IP address Secondary DNS IP Specifies a secondary DNS IP address HTTP Port Number Specifies a HTTP port number Default value is 80 Telnet Port Number Specifies a Telnet port number Default value is 23 POP3 Port Number Specifies a POP3 port number Default value is 110 SMTP Port Number Specifies a SMTP port number Default value is 25 Incoming Email ...

Page 24: ...l List ACL Enable Enable or disable for controlling client IP addresses to access the system Network Connection Check Using This IP This entry specifies an IP address or a URL site that the NP system will ping periodically for verification of network connectivity If the network connection is down or inactive AutoPing is in off mode If this entry leaves blank net work gateway IP address will be use...

Page 25: ...m control command The subject field has the following fomat rcs For example sending email subject rcs and content admin admin help will get all email supporting command The user name is admin and password is admin After a command is executed a confirmation reply email is sent The destination of the replying email address is already defined in the Network Configuration Table A control command is no...

Page 26: ...Xtreme Power Conversion Corporation XPD0215SL User s Manual Page 26 Power Distribution Unit Appendix B Serial Console Port Interfaces ...

Reviews: