background image

P91 Lead Acid 2U User

s Manual 

Uninterruptible Power Supply 

Xtreme Power Conversion Corporation

 

Page 32 

 

 

 

 

P90, P90L, P90g, P90Lg, P91

 

 

50,000

 

 

Term of XPC Limited Warranty

 

 

T91

 

 

50,000

 

 

Term of XPC Limited Warranty

 

 

TX91, TX91L

 

 

50,000

 

 

Term of XPC Limited Warranty

 

 
 

This Load Protection Policy is not deemed "first dollar" coverage. XP

C’s 

obligation is reduced by  any  amounts 

that  the  Purchaser  is  entitled  to  recover,  from  other  sources  regarding  the  Connected  Equipment,  including, 

but  not  limited  to,  insurance,  other  warranty,  extended  warranty,  or  legal  liability,  regardless  of  whether  or 

not the Purchaser makes a claim for recovery.

 

 

 

Eligibility for Coverage Under the Load Protection Policy

 

1.  

The Product must be registered on the XPC website, 

www.xpcc.com

, within 10 days of purchase.

 

All  required  information  must  be  provided,  and  Purchaser  should  retain  a  copy  for  Purchase

r’s 

records.     When registering  on the website, Purchaser must  list  all connected equipment that is 

directly connected to the product.     Only those devices registered in that manner will be covered.

 

2.  

All Connected Equipment must be UL or CSA approved.

 

3.  

The  Product  must  be  plugged  into  a  properly  wired  and  grounded  outlet.  Use  of  input  surge 

devices,  extension  cords,  adapters,  ground  wires,  or  electrical  connections  not  manufactured  by 

XPC voids the XPC Load Protection Policy. No other surge protection device may be connected to 

the output sockets of the Product. The  installation must  comply with all applicable  electrical  and 

safety codes set forth pursuant to the NEC.

 

4.  

The  Product  must  have  undeniable  physical  evidence  of  a  Power  Disturbance  that  directly  and

 

proximately caused the damage;

 

5. 

The  Connected  Equipment  must  have  been  damaged  by  a  Power  Disturbance  on  a  properly 

installed,  grounded,  and  National  Electric  Code,  ("NEC"),  code-compliant  120,  208,  240  Volt  AC 

power  line  in  the  United  States  or  Canada,  by  a  Power  Disturbance  on  standard  telephone  land 

line or PBX telephone equipment line that is properly installed and connected to an RJ11 port on 

the  Product;  or  by  a  Power  Disturbance  on  a  standard  Local  Area  Network  connection  that  is 

properly  installed  and  connected  to  an RJ45  port on the  Product  and  (d)  is directly  plugged  into, 

and  properly  connected  to,  the  Product  in  its  original  condition  which  was  properly  operated 

when a Power Disturbance passed through the Product and (i) exhausts the protection capacity of 

the Product or (ii) damages the Product.

 

6.  

The Load Protection Policy does not apply if the Product has been operated in a failure mode or

 

not  in  compliance  with  XPC  operating  instructions  in  the  Product  user's  manual,  or  if  the 

Connected Equipment has not been operated in compliance with the instructions and manuals of 

its manufacturer/vendor.

 

7.  

This  policy  is  null  and  void  if,  XPC  determines,  in  its  sole  discretion,  that  the  Product  has  been

 

tampered with or altered in any way.

 

 

 

What is Not Covered Under the Load Protection Policy:

 

Summary of Contents for P91g Series

Page 1: ...P91 P91g Lead Acid Online UPS 1000VA 2000VA 3000VA Models User Installation Manual www xpcc com 2021 Xtreme Power Conversion Corporation All rights reserved Rev 10 21 21...

Page 2: ...Setup the UPS 7 2 5 Battery Replacement 11 2 6 Battery Kit Assembly 12 3 Operations 15 3 1 Button operation 15 3 2 LCD Panel 15 3 3 Audible Alarm 16 3 4 LCD display wordings index 17 3 5 UPS Setting...

Page 3: ...Place cables in such a way that no one can step on or trip over them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no pr...

Page 4: ...ify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS capacitors To avoid electrical shock turn off the unit and unplug it form the A...

Page 5: ...to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment i...

Page 6: ...ure that nothing inside the package is damaged Please keep the original package in a safe place for future use 2 1 Rear panel view P91g models 1500 Model 2000 Model 3000 Model P91 models 1000 1500 Mod...

Page 7: ...ptible Power Supply Xtreme Power Conversion Corporation Page 5 5 USB communication port 6 RS 232 communication port 7 SNMP intelligent slot 8 Emergency power off function connector EPO 9 External batt...

Page 8: ...Rectifier PFC Dynamic Bypass Inverter Battery Charger The UPS is composed of mains input EMI RFI filters rectifier PFC inverter battery charger DC to DC converter battery dynamic bypass and UPS output...

Page 9: ...clearance of 100mm in the bottom of the UPS to avoid dust and high temperature 2 Place UPS It s equipped with fan for cooling Therefore place the UPS in a well ventilated area It s required to mainta...

Page 10: ...ttery pack s Note If you have multiple battery packs available connect them serially An example is shown in the diagram below connecting the second battery connector of the first battery pack to the f...

Page 11: ...onnection There are two kinds of outputs programmable outlets and general outlets Please connect non critical devices to the programmable outlets and critical devices to the general outlets During pow...

Page 12: ...able EPO function This UPS is equipped with EPO function By default the UPS is delivered from factory with Pin 1 and pin 2 closed a metal plate is connected to Pin 1 and Pin2 for UPS normal operation...

Page 13: ...er restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock 2 5 Battery Replacement When the icons of and are flashing in LCD display and alarm is...

Page 14: ...connect the battery wires Put the front panel back to the unit 2 6 Battery Kit Assembly NOTICE Please assemble battery kit first before installing it inside of UPS Please select correct battery kit p...

Page 15: ...embled battery packs on one side of plastic shells as below chart Step 4 Cover the other side of plastic shell as below chart Then battery kit is assembly well 4 battery kit Step 1 Remove adhesive tap...

Page 16: ...ation Page 14 6 battery kit Step 1 Remove adhesive tapes Step 2 Connect all battery terminals by following below chart Tapes Tapes Step 3 Put assembled battery packs on one side of plastic shells Step...

Page 17: ...g this button Confirm selection key Press this button to confirm selection in UPS setting mode Select Button Switch LCD message Press this button to change the LCD message for input voltage input freq...

Page 18: ...frequency load current and load percent k kilo W watt V voltage A ampere percent centigrade degree Hz frequency Load information Indicates the load level by 0 24 25 49 50 74 and 75 100 Indicates overl...

Page 19: ...ngs index Abbreviation Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS Low loss AO Active open AC Active close EAT Estimated autonomy time RAT Running autonomy time SD Shut...

Page 20: ...Vac For P91 models you may choose the following output voltage 100 presents output voltage is 100Vac 110 presents output voltage is 110Vac 115 presents output voltage is 115Vac 120 presents output vol...

Page 21: ...ting range in parameter 3 is from 7V to 24V of the nominal voltage Default 12V For P91 models the setting voltage in parameter 3 is from 3V to 12V of the nominal voltage Default 6V 06 Bypass enable di...

Page 22: ...els 55 59Hz setting the frequency low loss point from 55Hz to 59Hz Default 57 0Hz 09 Programmable outlets enable disable Interface Setting Parameter 2 Enable or disable programmable outlets ENA Progra...

Page 23: ...ty as following table for reference Battery capacity AH Total charging current A 7 20 2 20 40 4 40 60 6 60 8 14 Charger boost voltage setting Interface Setting Parameter 2 Set up the charger boost vol...

Page 24: ...ing mode Description LCD display Online mode When the input voltage is within acceptable range UPS will provide pure and stable AC power to output The UPS will also charge the battery in online mode E...

Page 25: ...4 x Over input current 49 x 3 8 Warning indicator Warning Icon flashing Code Alarm Low Battery Sounding every 2 seconds Overload Sounding every second Over input current Sounding 2 beep every 10 secon...

Page 26: ...ttery is incorrectly connected Check if all batteries are connected well Fault code is shown as 27 on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is fault...

Page 27: ...r at least 5 hours and then check capacity If the problem still persists consult your dealer Batteries defect Contact your dealer to replace the battery Fault code is shown as 2A on LCD display and al...

Page 28: ...are horizontal brackets tower pedestals user manual AVAILABLE OPTIONS Bypass distribution XBDM power distribution XPDU 4 post rail kit 2 post shelf kit wall mount bracket Depending on load level P91g...

Page 29: ...930W 16A 125Vac input 2000VA 1850W 16 7A 120Vac input 2000VA 1740W 17 4A 115Vac input 2000VA 1640W 18 2A 110Vac input 1800VA 1500W 18A 100Vac input P91 3000 100 125Vac 50 60Hz 24A 1 100 110 115 120 12...

Page 30: ...P90 BP72 Used with UPS Models P91 1500 P91g 1500 P91 2000 P91g 2000 P91 3000 P91g 3000 Battery Type 12V 9Ah 12V 9Ah 12V 9Ah 12V 9Ah Battery Numbers 6 12 8 12 Dimensions WxDxH 17 2 x 18 9 x 3 5 in 17...

Page 31: ...echnician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Mater...

Page 32: ...the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjecte...

Page 33: ...r d the total amount of all payment s you have or are entitled to receive from insurance other warranties extended warranties a legal liability claim or from other sources or persons for the damaged C...

Page 34: ...vice may be connected to the output sockets of the Product The installation must comply with all applicable electrical and safety codes set forth pursuant to the NEC 4 The Product must have undeniable...

Page 35: ...ILITY OF SUCH DAMAGE SUCH DAMAGES INCLUDE BUT ARE NOT LIMITED TO LOSS OF PROFITS LOSS OF SAVINGS OR REVENUE LOSS OF USE OF THE PRODUCT OR THE CONNECTED EQUIPMENT OR ANY ASSOCIATED EQUIPMENT LOSS OF SO...

Page 36: ...nt to XPC if it chooses to reimburse the Purchaser for the fair market value of the Connected Equipment XPCs maximum liability shall be reduced to reflect all such other payments or sources of recover...

Reviews: