background image

www.XtremeAirUsa.com

                                                                    PAGE 

7

 

 

STEP 3: Install support brackets 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 4: Install Chimney 

Important note: first make sure your ductwork is pulled down about 6 inch longer than the chimney 

 

 

 

 

 

 

 

 

 

 

.

STEP 5: Attach Hood Body 

 
MODEL PX04-I36, PX04-I42, PX05-I36, PX05-I42, PX06-I36, PX06-I42 – SKIP THIS STEP 
 
 
 
 
 
 
 

1.

 

Attach  multiple  hoses  brackets  vertically  outside  the  4 
corner of the ceiling bracket as show in Figure 3A. 

 

Figure 3A 

2. Attach brackets vertically inside of the 4 multiple holes 
brackets installed in previous step (3A).   

Note: make sure extend the brackets to the appropriate 
length. (the bottom of the hood should be 26”-30” above the 
cook top) 

     

 

 

1.

 

Slide inner and outer chimney sleeve over support 
brackets, covering the ceiling bracket 

2.

 

Screw inner chimney into place at the top of ceiling 
bracket 

3.

 

Lift the outer chimney all the way up to ceiling, USE 
screw driver to hold it from falling down 

 
Note: 

To avoid scratching the chimney, extend the inner upper 

chimney 

slowly 

and 

carefully 

to  the  chimney-mounting 

bracket

 

 

Mount the canopy glass to the hood. 

Summary of Contents for PX01-I36

Page 1: ...PAGE 1 Island Mount Range Hood IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY PRO X SERIES INSTALLATION GUIDE USER S MANUAL PX01 I36 PX01 I42 PX06 I36 PX06 I42 PX04 I36 PX04 I42 PX05 I36 PX05 I42 ...

Page 2: ...ds Do not store flammable or explosive materials in adjacent cabinets or surrounding areas Disclaimer The manufacturer and or distributor reseller decline all responsibility in the event of failure to ob serve the instructions provided for installation maintenance and suitable use of the product The manufacturer and or distributor reseller shall NOT be responsible for any injury due to negligence ...

Page 3: ...wiring must be properly installed insulated and grounded Before servicing or cleaning unit turn power OFF and un plugged OPERATION Use high settings on cooking range only when necessary Keep all fan baffle spaces filter grease tunnel oil container and grease laden surfaces clean Grease should not be allowed to accumulate on fan baffle spaces filter grease tunnel and oil container Never allow the f...

Page 4: ...system must have a damper If roof or wall cap has a damper do not use damper supplied for some models only with the range hood For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 or bigger vent work ALWAYS when possible reduce the number or t...

Page 5: ...dequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances TOOL YOU WILL NEED Maker or pencil Stud finder Measuring tape Powered screwdriver or drill Flat Phillips screwdrivers Level Drill with 1 1 4 7 9 mm drill bits Jigsaw or keyhole saw Cabinet...

Page 6: ... Drop the ducting and electrical work through the ceiling NOTE Use threaded drywall anchors only when mounting the hood on sheet Rock Mounting the hood on ceiling rafter studs or lumbers is a must 1 Put a thick protective covering over counter top cook top or range to protect from damage or dirt 2 Find and mark the center point directly above your cook top 3 Place the ceiling bracket on the ceilin...

Page 7: ...ckets vertically inside of the 4 multiple holes brackets installed in previous step 3A Note make sure extend the brackets to the appropriate length the bottom of the hood should be 26 30 above the cook top 1 Slide inner and outer chimney sleeve over support brackets covering the ceiling bracket 2 Screw inner chimney into place at the top of ceiling bracket 3 Lift the outer chimney all the way up t...

Page 8: ...ectly under the support brackets 2 connect power plug and connect the ductwork to the range hood HINT Due to the heavy weight of this range hood use vertical jack to lift and hold the hood in place is highly recommend it 3 Screw hood to the support brackets on all 4 corners as show 5A A DROP OIL TUNNEL INTO THE INSIDE HOOD BODY SLOT REFER TO LEFT FIGURE B INSTALL BAFFLE FILTERS refer to Figure on ...

Page 9: ...SCREEN CONTROL FOR PX02 models ONLY Note This range hood is equipped with remote control and smoke sensor that will self calibrate within 5 seconds when the range hood is first electrically activated Self calibration will be set when the range hood beeps LCD panel will turn off automatically after a period of inactivity A DROP 2 OIL TUNNELS INTO INSIDE HOOD BODY SLOT AT BOTH ENDS REFER TO LEFT FIG...

Page 10: ...ht button to turn the lights on or off 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button quickly 1 15 minutes Timer begins to countdown immediately when it reaches 0 the blower will shut off 3 Display screen will show flashing clock if timer is working Whi...

Page 11: ...ction 1 While the blower motor is not running touch and hold Decrease Value button over 3 seconds to enter timer mode 2 Adjust to desired period of delay off timer by touching Increase Value or Decrease Value button minimum 1 minute to maximum 15 minutes This setting will be saved immediately F Activating the timer function While the blower motor is running touch and hold Power button for over 3 s...

Page 12: ...heck if duct is clogged or if damper unit half circular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow 4 The lights work but the blower is not spinning at all is stuck or is rattling The blower might be jammed or scraping the bottom due to shipping damage Please contact us immediately The motor is defective p...

Page 13: ...ool scoring pads which will scratch and damage the stainless steel surface For heavier soil use liquid degrease such as Formula 409 or Fantastic brand cleaner If hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution onto or into the control panel Follow directions of the stainless steel cleaner CAUTION Do not leave o...

Reviews: