3.3.2. MCM-W HyperTerminal Commands ........................................................................... 39

 

A. MCM-W HyperTerminal Command – system ..............................................................40

 

B. MCM-W HyperTerminal Command – counter .............................................................43

 

C. MCM-W HyperTerminal Command – ip .......................................................................43

 

D. MCM-W HyperTerminal Command – ddmi ..................................................................44

 

E. MCM-W HyperTerminal Command – LLF ....................................................................44

 

F. MCM-W HyperTerminal Command – cls ......................................................................44

 

G. MCM-W HyperTerminal Command – logout................................................................44

 

4. MCM-W General Specifications................................................................................................ 45

 

 
 

5

E-mail: [email protected]

Website: www.Xtramus.com

XTRAMUS TECHNOLOGIES

®

 

Summary of Contents for MCM-7S81-W

Page 1: ...MCM W Series Media Converter User s Manual USM Ver 1 3 ...

Page 2: ...us Technologies assumes no responsibility or liability for any errors or inaccuracies that may appear in the document Trademarks MCM W is a trademark or registered trademark of Xtramus Technologies All other trademarks and registered trademarks are the property of their respective owners Warranty Xtramus Technologies warrants for the hardware provided along with this document under proper usage an...

Page 3: ...1 35 2 Add DDMI function on page 28 3 Adding more information about product features and main applications on page 7 2012 02 14 1 3 1 Page 31 adding Link Loss Forwarding section 2 Page 38 changing the MCM W HyperTerminal main screen figure 3 Page 39 changing the MCM W HyperTerminal main screen figure and adding ddmi llf commands in the table 4 Page 40 change command devname to name 5 Page 40 addin...

Page 4: ...1 Application for University 21 2 3 2 Application for Online Game Company 22 2 3 3 Application for Home Users 23 3 MCM W Management 24 3 1 Managing MCM W with Management Webpage 24 3 1 1 Accessing MCM W Management Webpage 25 3 1 2 MCM W Management Webpage Overview 26 3 1 3 MCM W Management Webpage System 27 A System Information 27 3 1 4 MCM W Management Webpage DDMI 28 3 1 5 MCM W Management Webpa...

Page 5: ...nd counter 43 C MCM W HyperTerminal Command ip 43 D MCM W HyperTerminal Command ddmi 44 E MCM W HyperTerminal Command LLF 44 F MCM W HyperTerminal Command cls 44 G MCM W HyperTerminal Command logout 44 4 MCM W General Specifications 45 5 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 6: ...solid All MCM Ws are equipped with real time LEDs which display the status of each port thus allowing users to view network status easily MCM W provides an easy to access Management Webpage allowing users to view system status counters and network statistics Also MCM W supports MIB Counter Report including counters such as Packet Byte Broadcast packet Pause Frame Length 64 Bytes Length 65 127 Byte...

Page 7: ...oring Interface allowing users to view status such as Temperature Supply Voltage Tx Bias Current Tx Power dBm and Rx Power dBm Key Advantages Fast connection with multi function Provide reliable long distance connection Port supported SFP SFP RJ45 XFP and CX4 Small portable size case Plug and play without extra configuration Main Applications Media converter for network backbone Connection between...

Page 8: ...media converting platforms for different types of media Please see 1 3 2 MCM W Front Panel for more detailed information Cooling Fan Cooling fan for ventilation All MCM W expect MCM 7S81 W have cooling fans installed Back Panel MCM W s back panels allow users to access their management web pages or making configurations via hyper terminal softwares Also MCM W s power jack is located on the back pa...

Page 9: ... RJ45 Interface Port B SFP Data Transfer Rate 1000 Mbps Ethernet Mode 1000Base T 1000Base X LED Status Green ON MCM 7S81 W is power on Power Green OFF MCM 7S81 W is power off Green ON MCM 7S81 W is booting properly and is ready for tests SYS Yellow ON Error occurred when booting MCM 7S81 W Green ON Port A B is connected A B Green Blinking Port A B is transmitting receiving data User defined LED Us...

Page 10: ...ower Green OFF MCM 8S22 W is power off Green ON MCM 8S22 W is booting properly and is ready for tests SYS Yellow ON Error occurred when booting MCM 8S22 W Green ON Port A B is connected A B Green Blinking Port A B is transmitting receiving data User defined LED User defined LED Note All LEDS will be off when upgrading FPGA Firmware 10 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNO...

Page 11: ...ower Green OFF MCM 8S23 W is power off Green ON MCM 8S23 W is booting properly and is ready for tests SYS Yellow ON Error occurred when booting MCM 8S23 W Green ON Port A B is connected A B Green Blinking Port A B is transmitting receiving data User defined LED User defined LED Note All LEDS will be off when upgrading FPGA Firmware 11 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNO...

Page 12: ... on Power Green OFF MCM 8S82 W is power off Green ON MCM 8S82 W is booting properly and is ready for tests SYS Yellow ON Error occurred when booting MCM 8S82 W Green ON Port A B is connected A B Green Blinking Port A B is transmitting receiving data User defined LED User defined LED Note All LEDS will be off when upgrading FPGA Firmware 12 E mail sales xtramus com Website www Xtramus com XTRAMUS T...

Page 13: ...SR 10GBase CX4 LED Status Green ON MCM 8S62 W is booting properly and is ready for tests SYS Yellow ON Error occurred when booting MCM 8S62 W Green ON Port A B is connected A B Green Blinking Port A B is transmitting receiving data Note All LEDS will be off when upgrading FPGA Firmware 13 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 14: ...ower Green OFF MCM 8S33 W is power off Green ON MCM 8S33 W is booting properly and is ready for tests SYS Yellow ON Error occurred when booting MCM 8S33 W Green ON Port A B is connected A B Green Blinking Port A B is transmitting receiving data User defined LED User defined LED Note All LEDS will be off when upgrading FPGA Firmware 14 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNO...

Page 15: ...r on Power Green OFF MCM 8S83 W is power off Green ON MCM 8S83 W is booting properly and is ready for tests SYS Yellow ON Error occurred when booting MCM 8S83 W Green ON Port A B is connected A B Green Blinking Port A B is transmitting receiving data User defined LED User defined LED Note All LEDS will be off when upgrading FPGA Firmware 15 E mail sales xtramus com Website www Xtramus com XTRAMUS ...

Page 16: ...series to a network thus allowing users to access MCM W s management web pages B Diagnostic Port 2 5mm Phone Jack for connecting PC s RS 232 port thus allowing users to make configurations via hyper terminal softwares C Power Jack DC 12 V Power Jack 16 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 17: ... in Ethernet 10GBASE T Cables 10GBASE T works up to 55 m 180 ft with existing Category 6 cabling In order to allow deployment at the usual 100 m 330 ft the standard uses a new partitioned Category 6a cable specification designed to reduce crosstalk between UTP cables The table down below is a reference regarding to UTP cable categories UTP Cable Categories References Cat 5 Provides performance of ...

Page 18: ...th 1310 nm wavelength connection on single mode fiber via IEEE 802 3 Clause 49 64B 66B Physical Coding Sub layer PCS using a line rate of 10 3125 Single mode optical cabling is used to interconnect transceivers at a distance spaced at 10 kilometers 6 2 mi but it can often reach distances of up to 25 kilometers 16 mi with no data loss Fabry Pérot lasers are commonly used in 10GBASE LR optical modul...

Page 19: ...Just plugging the RJ45 connector into the port of 10Gbps and it is ready to work When connected properly the Link ACT LED located under the RJ45 Port will be on accordingly 2 2 2 10GBASE R Optical Fiber Please see the figure down below for connecting the optical fiber transceiver and MCM W s SFP Port 19 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 20: ...for transmitting The picture here is called LC connector that can attach to SFP transceiver Transceiver Connector SFP XFP Transceivers can be plugged into MCM W s SFP XFP Ports SFP XFP Transceivers are active components that consume power from MCM W and are capable of converting signals between optical data flow and electronic data flow For different transmission purpose the component inside SFP f...

Page 21: ...ode optical fiber with 10BASE LR mode which can extend the distance beyond tens of kilometers C MCM W which is located at the computer center of university D After the conversions made by MCM W expensive equipments for transmitting receiving network data via optical fiber are not required anymore E Full 10Gbps Ethernet switches may be exceeding your budget or not available Some 1Gbps switches rese...

Page 22: ...E LR mode which can extend the distance beyond tens of kilometers D MCM W which is located at the control room of the game company E After the conversions made by MCM W expensive equipments for transmitting receiving network data via optical fiber are not required anymore F Depending on the network loading requirements Ethernet Switch with full 10Gbps ports or partial 10Gbps 1Gbps ports should be ...

Page 23: ...he central office The building on the right is one of the buildings served by the central office The white or gray blocks represent separate rooms or office spaces within the same building Descriptions A ISP Central Office B Network connection via optical fiber C Installation of MCM W for media conversion D Network connection via copper wire It can be Cat 6a cable under 300 meters or telephone lin...

Page 24: ...ging MCM W with Management Webpage MCM W Series is embedded with a management webpage and can be accessed by connecting MCM W Series Management Port to the network which your PC is connected to via an RJ45 cable Before accessing to MCM W Series configuration webpage with your PC s web browser please set the network according MCM W Series default IP Address 192 168 1 8 The figure down below is an e...

Page 25: ... the User Name and Password for MCM W Series configuration webpage Default User Name admin Default Password admin Please note that the User Name and Password are case sensitive For safety issues it is highly recommended that you should change the User name and Password when logging to MCM W Series management webpage for the first time MCM 8S33 W lated After inputting MCM W Series management webpag...

Page 26: ... System You can view system information here in this field DDMI Shows the temperature supply voltage Tx bias current Tx Power and Rx Power Management This option allows you to make settings such as MCM W series IP address SNMP or user accounts USC Setting This option allows you to turn ON OFF USC set the USC type and USC address Counter You can view MCM W Series counter reports with this option Ma...

Page 27: ...rature Port A SFP Factory The manufacturer of the transceiver plugged in Port A Port B SFP Factory The manufacturer of the transceiver plugged in Port B XFP Wavelength The wavelength of Port A B Management Port IP Mode This field displays how MCM W Series acquires its IP address Static MCM W Series IP subnet mask and gateway addresses are assigned manually DHCP MCM W Series IP subnet mask and gate...

Page 28: ...urrent Tx Bias Current the maximum minimum Tx Bias Current supported and the warning maximum Tx Bias Current Tx Power mW Shows the current Tx Power the maximum minimum Tx Power supported and the warning maximum Tx Power Rx Power mW Shows the current Rx Power the maximum minimum Rx Power supported and the warning maximum Rx Power Note Some transceiver can t support DDMI function or can only capture...

Page 29: ... the sections for detail descriptions about settings available in Management A IP Configuration IP Configuration IP Mode You can choose how MCM W acquires its IP subnet mask and gateway addresses There are two modes available Static You have to input MCM W s IP subnet mask and gateway addresses manually in the fields down below DHCP MCM W acquires its IP subnet mask and gateway addresses automatic...

Page 30: ...t the password here in this field Please note that the password must contain at least 5 alphanumeric characters and is case sensitive Confirm New Password Please input the password here again for confirmation Apply Apply the changes you ve made here C System Configuration System Configuration System Contact Input the contact information for MCM W here in this field System Location Input the system...

Page 31: ...that has both WRITE and READ privileges Apply Apply the changes you ve made here E Link Loss Forwarding Link Loss Forwarding Settings ON Enable Link Loss Forwarding function OFF disable Link Loss Forwarding function Apply Apply the changes you ve made here 31 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 32: ...s USC Universal Stream Counter Setting USC ON OFF Turn ON OFF the USC Universal Stream Counter USC Type When the USC is turn ON you may choose the type of USC in this option USC Address After choosing the type of USC input the USC Address in this field Apply Apply the changes you ve made here 32 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 33: ... Counter and Port A B USC Please see the section below for more detailed description A Device Counter The Counter Report can display statistics reports of MCM W s Port A B Device Counter Clear Clear all statistics displayed in the table 33 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 34: ...ou can see the Counter Report based on the type of USC Universal Stream Counter chosen in USC Setting Please see the 3 1 5 MCM W Management Webpage USC Setting 34 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 35: ... F W Firmware Browse Click the Browse button to choose the firmware file you would like to upgrade MCM W s firmware files are in the format of bin Send Click this button to start upgrading MCM W s firmware Note All LEDS will be off when upgrading FPGA Firmware Please DO NOT power off your MCM W C Update FPGA Update FPGA Browse Click the Browse button to choose the FPGA file you would like to upgra...

Page 36: ...tion F Config Upload Config Upload Browse Click the Browse button to choose the config file you would like to upload to MCM W MCM W s config files are in the format of cfg Send Click this button to start uploading MCM W s config file G Factory Defaults Factory Defaults Restore You can set all MCM W s settings to the default value by clicking the Restore button Please note that all unsaved data set...

Page 37: ...gs installations and HyperTerminal commands for other MCM Ws are quite the same and can be related 3 3 1 HyperTerminal Settings for MCM W After connecting the PC s serial port to MCM W s Console Port via a 2 5mm Phone Jack to RS 232 cable please start the HyperTerminal software installed on your PC and establish connection according to the steps listed down below Establishing Connection with MCM W...

Page 38: ...lick OK to continue Click the Enter key on your keyboard to start setting MCM W via HyperTerminal To log in please type MCM W s user name and password Default User Name admin Default Password admin Both the User Name and Password are case sensitive If you change MCM W s user name and password with MCM W s configuration webpage please log in with the new user name and password here 38 E mail sales ...

Page 39: ...mation ip ip The ip command allows you to view MCM W s current IP settings or configure these settings ddmi ddmi The ddmi command allows you to view the Digital Diagnostics Monitoring Interface LLF llf The LLF command allows you to enable disable the Loss Link Forwarding function cls cls The cls command allows you to clear HyperTerminal screen logout logout The logout command allows you to log out...

Page 40: ...MCM W name set The system name set device name command allows you to view the device name assigned to MCM W show The system location show command allows you to view MCM W s current location location set The system location set command allows you to set MCM W s current location show The system contact show command allows you to view MCM W s current contact information contact set The system contact...

Page 41: ...are quite the same and can be related 1 Type in system update firmware and click enter Press Y to proceed and start upgrading firmware or press N to cancel 2 Press Transfer on HyperTerminal s menu bar and choose Send File 3 A Send File window will pop up Please set the Protocol to Xmodem and click the Browse button 4 Choose the firmware you would like to upgrade to and click Open 41 E mail sales x...

Page 42: ...ill reboot when finishing upgrading its firmware reset The system reset command allows you to reset all MCM W s settings back to the default values system Contd reboot The system reboot command allows you to reboot MCM W Please note that all unsaved settings will be lost after rebooting 42 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...

Page 43: ...ormation of MCM W s IP status dhcp The ip mode dhcp command allows you to set MCM W s IP acquiring mode to DHCP allowing MCM W to acquire IP automatically from DHCP server mode static The ip mode static command allows you to set MCM W s IP acquiring mode to Static allowing you to set IP Subnet Mask Gateway IP manually address The ip address IP Address command allows you to set MCM W s IP address F...

Page 44: ...s you to enable the Loss Link Forwarding function while The llf disable command allows you to disable the Loss Link Forwarding function llf show The llf show command allows you to see if the Loss Link Forwarding function is enabled or disabled F MCM W HyperTerminal Command cls Command Descriptions cls cls The cls command allows you to clear HyperTerminal screen G MCM W HyperTerminal Command logout...

Page 45: ...er Report Packet Byte Broadcast packet Pause Frame Length 64 Bytes Length 65 127 Bytes Length 128 255 Bytes Length 256 511 Bytes Length 512 1023 Bytes Length 1024 1518 Bytes Unicast packet Multicast packet CRC Error IP Checksum Error Counter Report Under size packet Over size packet Hardware Temperature Operating 0o C 40o C 32o F 104o F Storage 0o C 50o C 32o F 122o F Humidity non condensing Opera...

Page 46: ...ts and company names are trademarks of their respective corporations Copyright 2012 Xtramus Technologies all rights reserved Do not reproduce redistribute or repost without written permission from Xtramus Doc USM_MCM W _V1 2_ENG_ 20120214 46 E mail sales xtramus com Website www Xtramus com XTRAMUS TECHNOLOGIES ...