Alarm management
• Each detector can trigger 2 Alarm outputs
• Alarm 1: Alarm in main zone, creep zone (zone 1 or S/M/L)
• Alarm 2: Battery level low, needs to be replaced
• Alarm 1&2: Any kind of tamper alarm
• A 120 seconds absence of any kind of message from the detector
(caused by its destruction, jamming, completely depleted batteries, etc.)
will trigger an additional Alarm on the associated receiving panel = >
Inactivity
• Thus, *
three
* outputs per detector are needed to communicate all
events from and about a detector to a connected Fasttrace (or any
other kind of alarm management device)
Summary of Contents for ADPRO PRO
Page 1: ...ADPRO PRO Passive Infrared Detector Training...
Page 10: ...Field test by perimeter security experts Freihoff and Piendl...
Page 11: ...Field test by perimeter security experts Freihoff and Piendl...
Page 16: ...Creepzone Video...
Page 25: ...Flipchart multi channel segmented mirror...
Page 40: ...Pole mounting only Remove break outs from side covers...
Page 41: ...Install side covers for brackets Note break outs for pole mounting only...
Page 44: ...Pole mounting Top view Exposure 360PROtect Alignment...
Page 46: ...Open bracket by pressing screwdriver pen etc through top hole...
Page 47: ...Feed installation cable and bracket switch wires through bracket...
Page 53: ...Prepare cable seal Cut into cable seal and tear off one knob for each cable used...
Page 55: ...Close lid tighten top screws...
Page 56: ...Place scope on detector for alignment...
Page 58: ...Remove scope and place iCommision...
Page 63: ...Fasttrace intelligent double knock and low visibility mode...
Page 64: ...iPIR Solutions PIR plus Fasttrace...
Page 71: ...Installation Tools and Accessories...
Page 75: ...Use of telescope in various situations...
Page 80: ...iCommission remote vertical alignment tool...
Page 83: ...Xtralis Pty Ltd Confidential Information 83 Multilanguage...
Page 86: ...PRO E 85 Zone information Alarm in near left zone Alarm in far center zone...
Page 88: ...NEW PRO SW Features scope view Shows all new events Compass alarm Antimasking 360PROtect...
Page 97: ...ADPRO PRO PIR Wireless detectors...
Page 102: ...Certified Geographic Markets...
Page 123: ...Xtralis Pty Ltd Confidential Information 123 Intrinsically Safe Detectors...
Page 128: ...Second Step Energy Limitation and Fail Safe Xtralis Pty Ltd Confidential Information 128...
Page 147: ......
Page 148: ...ADPRO PRO IS Certification Name Plate Xtralis Pty Ltd Confidential Information 148...
Page 151: ...Intrinsically Safe PIR Terminal Connections...
Page 157: ...Barrier operation RS485 RS485...
Page 164: ...Design Consideration Wedge shaped Coverage 1 Termination examples...
Page 167: ...Example of bad installation Detectors aligned at heat source 1...
Page 168: ...Example of bad installation Detectors aligned at heat source 2...
Page 170: ...Example of bad installation Detector alignment looking down steeply...
Page 171: ...Example of bad installation Completely overgrown actual site...
Page 172: ...Example of bad installation Moving foliage water blocked view 1...
Page 173: ...Example of bad installation Moving foliage water blocked view 2...
Page 174: ...Example of good and bad installation Cleared area tight fence but missing termination...
Page 175: ...Example of good installation Cleared area termination of detection zone in the end...