Cost saving through easy installation
No trenches
No cable tubes
Less or nearly no cables
Shortest installation times
quicker ROI
No customer operational disturbance or process
interruption
Highest flexibility
Ideal for temporary security solutions e.g. construction
sites, outdoor museums, car dealer etc.
Summary of Contents for ADPRO PRO
Page 1: ...ADPRO PRO Passive Infrared Detector Training...
Page 10: ...Field test by perimeter security experts Freihoff and Piendl...
Page 11: ...Field test by perimeter security experts Freihoff and Piendl...
Page 16: ...Creepzone Video...
Page 25: ...Flipchart multi channel segmented mirror...
Page 40: ...Pole mounting only Remove break outs from side covers...
Page 41: ...Install side covers for brackets Note break outs for pole mounting only...
Page 44: ...Pole mounting Top view Exposure 360PROtect Alignment...
Page 46: ...Open bracket by pressing screwdriver pen etc through top hole...
Page 47: ...Feed installation cable and bracket switch wires through bracket...
Page 53: ...Prepare cable seal Cut into cable seal and tear off one knob for each cable used...
Page 55: ...Close lid tighten top screws...
Page 56: ...Place scope on detector for alignment...
Page 58: ...Remove scope and place iCommision...
Page 63: ...Fasttrace intelligent double knock and low visibility mode...
Page 64: ...iPIR Solutions PIR plus Fasttrace...
Page 71: ...Installation Tools and Accessories...
Page 75: ...Use of telescope in various situations...
Page 80: ...iCommission remote vertical alignment tool...
Page 83: ...Xtralis Pty Ltd Confidential Information 83 Multilanguage...
Page 86: ...PRO E 85 Zone information Alarm in near left zone Alarm in far center zone...
Page 88: ...NEW PRO SW Features scope view Shows all new events Compass alarm Antimasking 360PROtect...
Page 97: ...ADPRO PRO PIR Wireless detectors...
Page 102: ...Certified Geographic Markets...
Page 123: ...Xtralis Pty Ltd Confidential Information 123 Intrinsically Safe Detectors...
Page 128: ...Second Step Energy Limitation and Fail Safe Xtralis Pty Ltd Confidential Information 128...
Page 147: ......
Page 148: ...ADPRO PRO IS Certification Name Plate Xtralis Pty Ltd Confidential Information 148...
Page 151: ...Intrinsically Safe PIR Terminal Connections...
Page 157: ...Barrier operation RS485 RS485...
Page 164: ...Design Consideration Wedge shaped Coverage 1 Termination examples...
Page 167: ...Example of bad installation Detectors aligned at heat source 1...
Page 168: ...Example of bad installation Detectors aligned at heat source 2...
Page 170: ...Example of bad installation Detector alignment looking down steeply...
Page 171: ...Example of bad installation Completely overgrown actual site...
Page 172: ...Example of bad installation Moving foliage water blocked view 1...
Page 173: ...Example of bad installation Moving foliage water blocked view 2...
Page 174: ...Example of good and bad installation Cleared area tight fence but missing termination...
Page 175: ...Example of good installation Cleared area termination of detection zone in the end...