XtendLan XL-GDB series User’s Guide
APPENDIX B: Acronym Definitions
Below are the definitions for the Alarms and PM acronyms.
DSLLos
The Loop is in Loss of Sync state when in Alarm state.
DSLLosW
Loss of Sync Word, the DSL SYNC word received was corrupted and when
this occurs continuously for more than 2 seconds, DSLLos will be declared.
DSLLosd
Far end user interface is not active when in Alarm state.
DSLSnr
Received DSL SNR value is lower than set value.
DSLAttn
DSL attenuation value is higher than set value.
DSLUAS15Min
PM Threshold alarm for 15-Minute count. Alarm will active when DSLUAS
value for the 15-minute interval islarger than set threshold value.
DSLSES15Min
PM Threshold alarm for 15-Minute count. Alarm will active when DSLSES
value for the 15-minute interval is larger than set threshold value.
DSLES15Min
PM Threshold alarm for 15-Minute count. Alarm will active when DSLES
value for the 15-minute interval is larger than set threshold value.
DSLUASDay
PM Threshold alarm for 1-Day count. Alarm will aktive when DSLUAS value
for the 1-Day interval is larger thanset threshold value.
DSLSESDay
PM Threshold alarm for 1-Day count. Alarm will activewhen DSLSES value
for the 1-Day interval is larger than set threshold value.
DSLESDay
PM Threshold alarm for 1-Day count. Alarm will aktive when DSLES value
for the 1-Day interval is larger thanset threshold value.
DTELos
Local DTE or Ethernet user interface is not active when in Alarm state.
ET1Los
The E1 or T1 interface does not have input signal, Loss of Signal (LOS).
ET1Lof
The E1 or T1 interface cannot obtain the input frame, Loss of Frame (LOF).
ET1Ais
The E1 or T1 interface is receiving an Alarm Indicator Signal.
ET1Rai
The E1 or T1 interface is receiving a Yellow alarm or Remote Alarm
Indication (RAI).
ET1UAS15Min
PM Threshold alarm for 15-Minute count. Alarm will active when ET1UAS
value for the 15-minute interval is larger than set threshold value.
ET1SES15Min
PM Threshold alarm for 15-Minute count. Alarm will active when ET1SES
value for the 15-minute interval is larger than set threshold value.
ET1ES15Min
PM Threshold alarm for 15-Minute count. Alarm will active when ET1ES
value for the 15-minute interval is larger than set threshold value.
ET1UASDay
PM Threshold alarm for 1 Day count. Alarm will aktive when ET1UAS value
for the 1-Day interval is larger than set threshold value.
ET1SESDay
PM Threshold alarm for 1 Day count. Alarm will aktive when ET1SES value
for the 1-Day interval is larger than set threshold value.
ET1ESDay
PM Threshold alarm for 1 Day count. Alarm will aktive when ET1ES value
for the 1-Day interval is larger than set threshold value.
93
Summary of Contents for XL-GDB101E
Page 87: ...XtendLan XL GDB series User s Guide 87...
Page 88: ...XtendLan XL GDB series User s Guide 88...
Page 89: ...XtendLan XL GDB series User s Guide 89...
Page 92: ...XtendLan XL GDB series User s Guide 92...
Page 95: ...XtendLan XL GDB series User s Guide APPENDIX D Loopback Illustration 95...