Step 2: Pull the power cable, video cable and controlling cable out via the cable 
out-going slot, then direct the dotted-line part of the bracket shown in the figure to the 
two corresponding pegs on the installed peg-board, then push the bracket downward 
until it locks in place. Make sure the bracket fits well with the peg-board, then tighten 
the screws on the bracket with the peg in underside part of the peg-board. (See Picture 
8) 

2-6. Installation of Half Ball

 

Locations with suspended top suit the  constant speed  ball  with in-ceiling 

installation style, which appears to be a hemisphere, having an elegant look and good 
concealment. The hemisphere style installation applies to solid locations of the ceiling. 
First, select the desired location, mark the outline of the upper housing on the ceiling 
with a pencil and make a corresponding-sized bore, then insert the upper housing into 
the ceiling, and press the spring pinning boards against the edge of the ceiling opening. 
After that, tighten the screw adjusting the spring pinning boards, and lock the upper 
housing in the ceiling tightly. For the sake of better safety, please use a metal wire 
rope to connect the top of the upper housing to a reinforced structure of the ceiling. 
(The wire rope is required to bear at least 5 times the weight of the  constant speed 
ball.) (See Picture 9)

 

Tightening screw 

Summary of Contents for PEDOMEOIR48023SD

Page 1: ...PEDOMEOIR48023SD Smart Constant Speed Dome Camera User Manual...

Page 2: ...breakdown arising from the dismantling or repairing of the unit without the company s authorization 2 Damage or breakdown arising from the client arranged transportation loading or unloading of the u...

Page 3: ...tomer s needs The Baud rate is also adjustable 10 The unit adopts DC12V power supply and separates from it the components that produce heat in the process of transformation which prolongs the durabili...

Page 4: ...ve Humidity below 90 RH 1 4 Styles of Installation and Ancillary Components Table 1 Styles of Installation and Ancillary Components of Constant Speed Ball Table 1 Styles of Installation and Ancillary...

Page 5: ...Installation Procedures 2 1 Outer shape and installation size Outer shape and installation size 2 1 1 2 Picture 1 Outer shape and size of wall mount style Picture 2 Outer shape and size of pendant mou...

Page 6: ...coding panel Camera power supply 12VDC GND Lens Zoom ZOOM Lens Focus FOCUS Lens Iris IRIS Lens Controlling public ground COM 3 Connecting Video Cable Connect BNC video outlet with the video output out...

Page 7: ...ll Installation of bracket of outer door Constant Speed Ball of wall mount type Picture 5 Size of bracket of outer door Constant Speed Ball of wall mount type Select the position for installation of C...

Page 8: ...pencil then install the fixing tray in the ceiling with expanding bolts not provided Please don t forget to push the connecting ports end of the power video and controlling integrated cable through t...

Page 9: ...to be a hemisphere having an elegant look and good concealment The hemisphere style installation applies to solid locations of the ceiling First select the desired location mark the outline of the up...

Page 10: ...er supply of Decoding PCB penal Camera lens controlling cable Camera lens control power Decoding PCB penal camera Provided with the integrated camera including power cables 2 Connection of temperature...

Page 11: ...uilt in Decoding PCB penal the control of the dome and camera lens is realized by setting up address protocol and baud rate through the decoding PCB penal 1 Address Setup As shown in the picture 10 an...

Page 12: ...amera power GND Lens common terminal Iris Focus Zoom 485 input Video outlet Power supply input 1 6 Address select switch 7 8 Baud rate select switch Key for left position setup Key for dome speed adju...

Page 13: ...7 100101 53 110101 6 000110 22 010110 38 100110 54 110110 7 000111 23 010111 39 100111 55 110111 8 001000 24 011000 40 101000 56 111000 9 001001 25 011001 41 101001 57 111001 10 001010 26 011010 42 10...

Page 14: ...ording to Table 2 or Table 3 as per the address you defined by yourself 2 Communication Baud Rate Setup As shown in picture 11 DIP 7 and DIP 8 of the 8 button coding switches are used to setup Baud ra...

Page 15: ...ommunication protocols with hard disk video recorder CNEUOL embedded Enterasys embedding DM embedding Hikvision embedding KCL YAAN SAMSUNG KIDICOM SX For information of hard disk video recorder protoc...

Page 16: ...Speed Ball Code Name of the function Definition for the keyboard operation Code Name of the function Definition for the keyboard operation 160 Begin with left right limiting position setup 140 Begin w...

Page 17: ...o action b The constant speed ball is in the state of pan auto touring If the constant speed ball is in the state of pan auto touring the tour should be stopped through the controlling device to avoid...

Page 18: ...ns After controlling pan tilt of the constant speed ball to desired position through the keyboard enter the number representing the preset position and LED displays the entered preset position number...

Page 19: ...position 1 to setup the first tour position Enter number 1 and press the PREVIEW key 3 Preview preset position 2 to setup the second tour position Enter number 2 and press the PREVIEW key 4 Preview p...

Page 20: ...camera s master board The operation requires the co operation of two people A Once the dome is installed well and power is on the constant speed ball starts a self check After the self check the posi...

Page 21: ...ired position press either S2 or S1 and then release it and the dome will stop moving Finally press the key S2 for about 2 seconds till the green indicator glistens once The glistening means the setup...

Page 22: ...he Default Position Move the constant speed ball to a key monitoring area through the controlling keyboard and enter number 164 124 from the keyboard and press the PREVIEW key and the setup is success...

Page 23: ...ut control Wrong setup of address code baud rate of the ball set Reset address code and baud rate of the ball set Wrong protocol Correct opposite connection or disconnection of RS458 cable Check conne...

Page 24: ...485 signal is weakening the driving of 485 convertor is not enough Replace the convertor...