XS Instruments Temp70 PT100 vio Instruction Manual Download Page 16

 

15  

 

UM Termometri Temp70 PT100 Vio ENG rev.0 05.04.2021

 

P9.3 Backlight mode

 

Access this setup menu to select the contrast mode to use for the display backlight:

 

 

INDOOR (In)

 – Recommended if you use the device indoors;

 

 

OUTDOOR (Out)

 –  Recommended if you use the device outdoors;

 

 

AUTO

  –  Default  option.  Thanks  to  the  brightness  sensor,  the  display  automatically  adapts  to  the 

environment conditions. This mode also ensures longer battery life.

 

 

P9.4 Brightness

 

Access this setup menu to choose between three different levels of display brightness:

 

 

LOW

 – low;

 

 

MEDIUM

 – medium;

 

 

HIGH

 – high.

 

Note

: Keeping the display bright always adversely affects battery life.

 

 

P9.5 Sleep mode

 

Access this setup menu to select whether and after how long activating the device Sleep mode:

 

 

OFF

: Sleep mode off.

 

 

2 MIN

: The instrument enters Sleep mode if no key is pressed for 2 minutes;

 

 

5 MIN

: The instrument enters Sleep mode if no key is pressed for 5 minutes.

 

When the device is in Sleep mode, the brightness of the display is reduced to a minimum, significantly saving 
battery consumption.

 

Note

: To exit from the Sleep mode and return the display to normal brightness, press ANY button. 

Once  the  display  brightness  is  activated,  the  buttons reacquire  their  function (paragraph "Key 
function").

 

 

P9.7 View difference 

 

Access this Setup to set how to view the temperature difference between the two channels as absolute 
value. This difference will be shown in the middle of the display in the screen with double channel.

 

 

Note

: the difference is shown also for recall of data saved, HOLD function, MAX/MIN recording 

and recall of MAX/MIN value.  

 

 

P9.8 Reset settings 

 

Access this Setup to restore the parameters of Settings menu.

 

The reset takes all the parameters to the default settings shown in the table above. 

 

 

Note

: after the Reset, the instrument returns in measure mode and all the parameters return to 

the default settings.

 

 

P9.9 Auto off

 

Access this setup menu to activate or deactivate the auto-shutdown of the instrument:

 

 

YES: 

The instrument automatically turns off after 20 minutes of inactivity;

 

 

NO:

 

The instrument remains always on, even if you are not using it.

 

IMPORTANT:

 The correct and systematic use of parameters P9.3 / P9.4 / P9.5 / P9.9 allows to significantly 

lengthen battery life.

 

 
 
 
 
 
 
 
 

Summary of Contents for Temp70 PT100 vio

Page 1: ...INSTRUCTIONS MANUAL Temp70 PT100...

Page 2: ...1 UM Termometri Temp70 PT100 Vio ENG rev 0 05 04 2021...

Page 3: ...es 6 Datasheet 6 Instrument description 7 Display 7 Keypad 7 LED 8 Setup 8 Supplied components 8 Start up 8 Switching On Off 8 Batteries replacement 8 Instrument transportation 9 Key Functions 9 Input...

Page 4: ...100 Vio ENG rev 0 05 04 2021 Warranty 18 Warranty period and limitations 18 Disposal of electrical devices 18 XS Instruments Via della Meccanica n 25 41012 Carpi MO ITALY Tel 39059 653274 Fax 39059653...

Page 5: ...ided ATTENTION for a dangerous situation with reduced risk which can cause material damaged data loss or minor or medium sized accidents if not avoided WARNING for important information about the prod...

Page 6: ...rs or in environments with conditions different from those mentioned in this manual Device maintenance If used correctly and in a suitable environment the instrument does not require maintenance proce...

Page 7: ...and automatic with integrated sensor Sleep mode Yes Auto switch off Yes after 20 minutes deactivable LED indication Yes Reading stability indicator Yes adjustable Low Med High Stability filter HOLD Ye...

Page 8: ...ing function MAX MIN if active OK Setup Key to confirm the values and enter into the setup menu from the meausure mode Up directional Key Save data for scrolling through menus and parameters Press fas...

Page 9: ...m by pressing the button The display initially activates all segments and then appears model and firmware of the instrument information about the calibration of the channel 1 and the channel 2 screen...

Page 10: ...different views while the two probes are connected channel 1 channel 2 and both channels simultaneously Into the setup menus press to return to measure mode Short To scroll and modify the values of th...

Page 11: ...ay FIXED Automatic Data Logger set INTERMITTENT Automatic Data Logger in operation Instrument connected to the DataLink software Device operation On the left side of the display through a string of di...

Page 12: ...ibration data P7 4 Select resolution P7 5 Stability filter P7 6 Reset settings P8 0 LOG SETTINGS P8 1 Log type P8 2 Clear data P9 0 SETTINGS P9 1 Temperature unit P9 2 Date and time P9 3 Backlight mod...

Page 13: ...resolution for the temperature reading 0 1 0 01 Factory Default settings Note changing the temperature resolution the temperature resolution for both channels will change too P7 5 Stability filter To...

Page 14: ...uisition mode MANUAL The data is acquired only when the user presses the button HOURS MINUTES Set a frequency range of automatic data acquisition With the direction keys move from MANUAL to HOURS or M...

Page 15: ...configuration menu In measure mode press button to access the SETUP menu Press the key or to move to SETTINGS menu P9 0 Press the key to access the menu Move with keys and to select the program to ac...

Page 16: ...ly saving battery consumption Note To exit from the Sleep mode and return the display to normal brightness press ANY button Once the display brightness is activated the buttons reacquire their functio...

Page 17: ...screen on the display a text string will flash MIN MAX REC 1 probe connected REC both probes connected Press the key once to check the maximum value reached up to that moment press it another time to...

Page 18: ...h the key or and confirm with the key In the middle of the display the correct temperature is displayed while the partial value of the calibration is displayed below it The adjustment changes the enti...

Page 19: ...acturer will repair or replace defective components This warranty is valid only and exclusively on the electronic parts of the device and does not apply if the product has been damaged used incorrectl...

Reviews: