CO2 Purge Solenoid Valve Deep-Cleaning Instructions
Remove the solenoid valve from the filler. Use the
release tool provided to disconnect the push-to-connect
fittings from the tubes.
Slide off the clip from the top of the coil assembly.
Remove the coil assembly off the center shaft. Unscrew
the shaft from the stainless steel base. It is not necessary
to unscrew the tubing adaptors from the stainless steel
base.
Now rinse out all the openings inside and outside of the
solenoid
valve,
removing
any
particulates
and
stickiness that may have accumulated.
Reassemble and replace in the filler.
Stainless steel valve body is marked #1 for input,
#2 for output.
Note:
Valve may leak if installed
backwards.
Note:
This maintenance is needed only when the filler is not performing properly.